5.0 Fault fi nding
29
Genie S
5.3 FAULT CODES & DIAGNOSTICS
DISPLA
Y
LOCK / RESET
GREEN
YELLOW
RED
LED1
RED
RED
LED2
Operating, raising pool temperature to 28°C
Up to temperature, 28°C
Low pool water fl
ow (Filter blockage?) or Low
primary water pressure (check guage on display)
‘OH2’
Flue gas over temperature.
Allow to
cool then investigate in Engineering Mode.
Reset with Button
‘GAS’
Gas Control Lockout. Unable to light
burner
, reset with Button.
OR
Flue Stat tripped.
Investigate cause. Reset on Flue Stat
FRONT P
ANEL
ON PCB
EXPLANA
TION
OFF
, no mains supply or failed power supply
Flashing
‘HI’
Condensate level high. Blocked? Clear
obstruction and allow control to auto reset .
‘SEr
’ alternating with pool temperature. Service
required, working hours has reached setpoint.