2.0 Requirements
10
Genie S
Fig. 1.0
2.13 FLUE TERMINAL POSITIONS
Minimum Distance
mm
A Directly below an opening, air brick, opening window etc
300
B Above an opening, air brick, opening window etc
300
C Horizontally to an opening, air brick, opening window etc
300
D Below gutters, soil pipes or drainpipes
75*
E Below eaves
200
F Below a balcony or car port roof
200
G From vertical drain or soil pipe
150
H From an internal or external corner or to an alongside boundary
300
I Above ground, roof or balcony level
300
J From a surface or a boundary line facing a terminal
600
K From a terminal facing a terminal
1200
L From a opening in a carport (e.g. door, windows) into the building 1200
M Vertically from a terminal on the same wall
1500
N Horizontally from a terminal on the same wall
300
P From a roof structure
N/A
Q Above the highest point of intersection on a roof
1200
Terminal adjacent to windows or opening on pitched and fl at roofs
The fl ue should not
penetrate the shaded
area
*
Only if combustible material is protected. Otherwise a clearance of 600mm should be allowed.
Fig. 1.0a
Terminals should be so
positioned as to avoid
products of combustion
entering openings into
buildings or other
fl
ues or
vents
Source of data : Building regulations Part J : 2010 Gas appliances up to 70 kW