EXTREME ELECTRIC BUTTERFLY VALVE

1.  

DEFINITION

Ball valve for isolating the flow in liquid handling systems. 

Design based on Standard  EN ISO 16136 in accordance with Directive 97/23/EC.

The valve is available with PVC-U, CPVC, PPH, PVDF and ABS discs and EPDM perox. and FPM sealing gaskets. The choice of material 

for the body and gaskets depends on the type of liquid to be carried and on the working temperature of the liquid, in accordance 

with the chemical resistance tables available on our website and the pressure/temperature chart in this Manual.

The electric actuator controls the positions of the valve (closed / open).

Lug-style valves have threaded inserts at both sides of the valve body. This allows them to be installed into a system using sets of 

bolts and no nuts. 

The valve is installed between flanges using a separate set of bolts for each flange. 

This setup permits either side of the piping system to be disconnected without disturbing the other side.

2.  

COMPONENTS

N

DESCRIPTION

MATERIAL

Q

1

Industrial Butterfly 
valve bare shaft

Body: PP-GR
Disc: PVC-U/CPVC/PPH/PVDF/ABS

1

2

Coupling bush

AISI-304 /AISI-316

1

3

Mounting clamp

PP-GR

1

4

Electric actuator

PA housing

1

6

Screw DIN-912

AISI-304 /AISI-316

4

7

Screw DIN-912

AISI-304 /AISI-316

4

8

Washer DIN-925

AISI-304 /AISI-316

4

9

Nut DIN-934

AISI-304 /AISI-316

4

2.1  

Actuated valve components

Fig. 1

Valve design

Flanged dimensions

Valve connections

Other connections

Actuator coupling (optional)

ISO 16136: 2006

EN 558-1,ANSI B16.5 Class 150,JIS B2220, BS/E

EN 1090-1

ISO15494, ISO15493, ISO10931

EN/ISO 5211

Summary of Contents for EXTREME ABS Series

Page 1: ...EXTREME SERIES BUTTERFLY VALVES LUG type Electric actuator INSTALLATION AND MAINTENANCE MANUAL PVC U EPDM FPM CPVC EPDM FPM PPH EPDM FPM PVDF EPDM FPM ABS EPDM FPM 0045...

Page 2: ...teriales termopl sticos Meets the requirements established by the European Union for PRESSURE EQUIPMENT ac cording to Directive 2014 68 UE PED category II module A2 in accordance with the harmo nized...

Page 3: ...r close the manual valve control is not recommended Before carrying out any maintenance operations on the pipe or valve ensure that the system has been depressurised by releasing the pressure and empt...

Page 4: ...s of the valve body This allows them to be installed into a system using sets of bolts and no nuts The valve is installed between flanges using a separate set of bolts for each flange This setup permi...

Page 5: ...OM DN65 AISI 304 1 1 13 O ring EPDM FPM 2 4 14 Screw DIN 912 AISI 304 AISI 316 1 1 15 Handle PP GR 1 16 Washer AISI 304 AISI 316 1 17 Lever PP GR 1 18 Pin AISI 304 1 19 Left spring AISI 304 1 20 Right...

Page 6: ...e will cause irreparable damage to the device All valves are electrically and hydraulically tested in the factory Valves will always be replaced in the event of any justifiable claim For more technica...

Page 7: ...12 Valve design Flanged dimensions Valve connections Other connections Actuator coupling ISO 16136 2005 EN 558 1 ANSI B16 5 Class 150 JIS B2220 BS E EN 1090 1 ISO15494 ISO15493 ISO10931 EN ISO 5211 N...

Page 8: ...nd closing of the disc Install the valve once the sockets are solvent bonded and dry to avoid problems with the adhesive entry of the latter into the valve Flanges must be well centred on the valve pa...

Page 9: ...sources Actuators do not have fuses and incorrect voltages can cause irreparable damage to the device J J Characteristics Thermostat controlled temperature Incorporation of a thermostat controlled 4W...

Page 10: ...12 Tap on the shaft 6 with a rubber mallet until the bearing 4 is exposed from the bottom Fig 11 Once the bearing is out remove the shaft 6 turn it and re insert it Fig 12 from the bottom Tap again u...

Page 11: ...ockets and valve Disassemble the valve and reassemble with concentric alignment observe the correct tightening sequence and torque The valve is not completely watertight in the sockets Misalignment be...

Page 12: ...Av Ram n Ciurans 40 PI Congost P6 La Garriga BCN Spain Tel 34 93 870 42 08 www cepex com cepex cepex com COPYRIGHT CEPEX S A U ALL RIGHTS RESERVED CODE C584075MELXT Version 1 3 2020 01...

Reviews: