6. Manual
Valves may be manually activated by the
following five options:
1. ALL of the valves may be manually
operated;
2. Valves attributed to a specific program
(A,B or C) may be manually operated;
3. More than one program may be manually
operated (e.g. A and B);
4. All of the Independent Program I valves
may be manually operated;
5. One or more of the Independent
Program I valves may be manually
operated.
1. Manual Operation of All Valves
Turn selector to manual mode. Symbol,
the word
ALL
and all of the programmed
valves will appear on display panel.
Press on . The word
HOLD
will
immediately appear on the screen for a
few seconds.
The valves will open according to the
following sequence: 1. Valves
programmed in Independent Program
I, from the smallest number upward.
2. Valves attributed to Program A, and
then Program B, and Program C.
2. Manual Operation of a Number of Valves
Attributed to Programs A, B, C or I
Press on . One of the programs symbol
will blink.
Press on until the required program
appears (for example, Program A).
Symbols of the valves attributed to this
program along with the symbol will
appear on the display panel.
Press on . The word HOLD will
immediately appear on the display screen
for a few seconds followed by the word
ON.
Valves attributed to the designated
program will open sequentially.
3. Manual Operation of one of the
Independent Valves I
Press on until I disappears, and the
symbol of the first valve attributed to
Group I blinks on the display panel.
Using select desired valve.
Press on . The word HOLD will appear
on the screen for a few seconds followed
by the word ON. The selected valve will
immediately open.
31
RAIN
OFF
TEST /
RESET
TIME / DAY
RUN
MANUAL
PROGRAM
WEEKLY /
CYCLIC
START
VALVES
DURATION
VALVE
DURATION
START
FERTILIZER
SENSOR
WATER
BUDGET
PROGRAM
A-B-C
INDEPENDENT
I
WEEKLY /
CYCLIC
MANUAL
The selector should be returned to the TIME/DAY mode
following modification or ending of the program.