![Cepex CMC-08-24 Installation And Operating Manual Download Page 27](http://html1.mh-extra.com/html/cepex/cmc-08-24/cmc-08-24_installation-and-operating-manual_2583348027.webp)
26
RAIN
OFF
TEST/
RESET
TIME / DAY
RUN
MANUAL
PROGRAM
WEEKLY/
CYCLIC
START
VALVES
DURATION
VALVE
DURATION
START
FERTILIZER
SENSOR
WATER
BUDGET
PROGRAM
A-B-C
INDEPENDENT
I
WEEKLY/
CYCLIC
1. Fertilization Supplement (F)
Fertilization time is set separatly for each individual valve.
Fertilization is added according to irrigation duration from 10% to 90% of the specific
valve irrigation time. Fertilization will always take place in the middle of the valve
irrigation time.
Example: A specific valve has been programmed for the duration of 60 minutes.
Fertilization supplement is set for 20%. Regular irrigation will be operated for the
first 24 minutes (without fertilization). Subsequently fertilization will be added for
the next 12 minutes (20% of the scheduled time); then regular irrigation will continue
for the next 24 minutes, so the line can be washed.
Turn selector to Fertilizer mode. Symbol of the fertilization valve (F) and % will
appear on display panel.
Press on until the valve you want to select, blinks.
00 % will appear on display panel. Press on . 00 will blink. Set the percentage
time using and as necessary.
Repeat the above steps for any other valve needed.
FERTILIZER
Advanced Programming
The selector should be returned to the TIME/DAY mode
following modification or ending of the program.