Page 30
Installation and Operation Manual - FW2900
ENGLISH
9.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14
½
" (368 mm)
11" (279 mm)
A
6" (152 mm)
6" (152 mm)
B
22" (559 mm)
22" (559 mm)
B
22" (559 mm)
22" (559 mm)
C
12" (305 mm)
12" (305 mm)
C
12" (305 mm)
12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
14 ½" (368 mm)
D
9 1/4" (235 mm)
9 1/4" (235 mm)
E
31 ½" (800 mm
31 ½" (800 mm)
E
31 1/4" (794 mm)
31 1/4" (794 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
F
21 ½" (546 mm)
21 ½" (546 mm)
9.1.1 With Heat Shield AC02762
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 1/4" (159 mm)
6 1/4" (159 mm)
B
4" (102 mm)
4" (102 mm)
E
13 1/4" (337 mm)
13 1/4" (337 mm)
C
3" (76 mm)
3" (76 mm)
F
12 ½" (318 mm)
12 ½" (318 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double
wall pipe connector can be used.