Century FW2600 Installation and Operation Manual
7
2 General Information on FW2600 (CB00018)
2.1 Appliance performance
(1)
Fuel type
Dry cordwood
Recommended heating area[*]
500
to
1,300
ft
2
(46
to
121
m
2
)
Firebox volume
1.7
ft
3
(0.048
m
3
)
Maximum burn time[*]
6
h
Maximum heat output (dry cordwood)
50,000
BTU/h (14.6 kW)
Overall heat output rate (min. to max.)
(2)(3)
11,400
BTU/h to
25,400
BTU/h
(3.3
kW to
7.4
kW)
Average overall efficiency
(3)
- EPA Cribs /
Douglas Fir
66.2% (HHV
(5)
)
71.6% (LHV
(4)
)
Average overall efficiency
(3)
- Dry cordwood
N/A (HHV
(5)
)
N/A (LHV
(4)
)
Optimum efficiency
(2)(6)
75.3
%
Average particulate emissions rate
(7)
4.0
g/h (EPA / CSA B415.1-10)
Average CO
(8)
132.2
g/h
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney
draft, heat loss factors, climate, fuel type and other variables. The recommended heated area for a given
appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature
in the designated area in case of a power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
(2)
Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content
between 19% and 25%.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.