At this moment release the TEST button to select feature
number 2. (L2 will turn off, and L1 will keep on flashing 2 times
and pausing to indicate that feature number 2 is selected).
NOTE:
The STATUS of the Feature is not changed yet, the
feature has only been selected to be changed!
If an incorrect Feature is selected, then remove and re-
apply power and repeat the procedure.
To change the STATUS value of a Feature: (
IM
page 31)
Press and hold
the TEST button while monitoring the
STATUS light:
(Continues from above example to set outoclose to ON status).
The L1 light will flash once and pause,
At this moment
release the TEST
button to give a
STATUS value of 1. The AUTOCLOSE feature has been set to
ON
NOTE:
Only after setting the STATUS, would the
AUTOCLOSE be turned ON.
(L2 will come back on, indicating that the STATUS has been
set.)
To change the COUNT value of a Feature: (
IM
page 31)
Press and hold
the TEST button while monitoring the
STATUS light:
After a slight pause, the STATUS light will start flashing . . . . . . .
regularly:
Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
Flash (6) ................ Flash (9), Flash (10).
At this moment release the TEST button to give a COUNT . . . . .
value of 10. This could for example be the preflash time.
(L2 will come back on, indicating the COUNT value has . . . . . .
been set). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remove the SET link.
7
E
XIT
P
ROGRAMMING
M
ODE