4
S
ELECT
EITHER
M
ASTER
OR
S
LAVE
S
ETUP
G
ET
I
NTO
P
ROGRAMMING
M
ODE
3
5
S
ET
THE
G
ATE
L
IMITS
Remove all power.
(IM
page 28)
Fit the SET link.
Reapply power
Press and hold the TEST button, release after 1 flash of L1.
Then again, press and hold the TEST button, and release after 1 or
2 flashes of the STATUS LED. (1 Flash=master, 2 Flashes=slave)
(
Installation Manual
page 29)
Press and hold TEST until the gate is closed, and then release.
NB:
THE GATE MUST CLOSE. IF IT OPENS :
Release the TEST button.
Swap the respective motor wires.
Press and hold TEST until gate is closed, and then
release.
Press and hold TEST until gate is open, and then release.
Press and release TEST (When setting up the MASTER gate, it will
close and then open to pedestrian.
IM page 29
).
If setting up the master gate, press and release TEST once more to
complete the setup (The MASTER gate will open fully, and the
SLAVE gate will move slightly).
Determine what features are required (See Table 2). (
IM
page 47)
Get into programme mode (as in Step 3), or continue from Step 5.
To select the Feature to Change: (
IM
page 31)
Press and hold
the TEST button while monitoring L1:
Example of how to select the AUTOCLOSE feature:
The L1 light will flash once and pause,
Then flash twice and pause ...
6
S
ETTING
A
DDITIONAL
F
EATURES
(
OPTIONAL
)