background image

Commissioning cont'd .....

29

29

ARROW SHOWS

CORRECT DIRECTION(S)

TO CLOSE GATE(S)

(VIEWED FROM INSIDE

THE PROPERTY)

L.H.S. GATE MOTOR

R.H.S. GATE MOTOR

}

PE

N

O

O

PE

N

CLO

SE

D

S

CLO

ED

CO

M

M

ON

CO

M

M

ON

SWOP MOTOR POLARITY TO
CHANGE MOTOR DIRECTION

MOTOR

MOTOR

EARTH
WIRE

EARTH
WIRE

TRIGGER CONTROL CARD

MAKE SURE MOTOR DIRECTION(S) CORRESPOND(S) WITH STATUS LED.
(COMPARE FIG 1 AND FIG 2 BELOW).

SWOP MOTOR WIRES TO GIVE CORRECT MOTOR ROTATION (IF NECESSARY).  (SEE FIG 3a BELOW).

TEST THAT MOTOR STOPS WHEN IT HITS THE LIMIT SWITCH.

SWOP LIMIT SWITCH WIRES IF MOTOR DOES NOT STOP ON LIMIT SWITCH (SEE FIG 3b BELOW).

SWOP TO STOP MOTOR(S) ON LIMIT(S) (IF NECESSARY)

--

--
--

--

--

}

}

SET MOTOR AND LIMIT SWITCH POLARITY

FIG 1

FIG 2

FIG 3a

CONNECTOR BLOCK

IN MOTOR

FIG 3b

x

x

x

x

CP77

CONTROLLER

CP87

CONTROLLER

FAST FLASH 
SLOW FLASH
LED ON
LED OFF

CLOSING
OPENING
GATE OPEN
GATE CLOSED

STATUS

STATUS

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Auto-Mate

Page 1: ...Latest Revision 08 03 04 Document Ref 1068 D 01 0052_4 SWING GATE OPERATORS INSTALLATION MANUAL Au o Ma e t t Ma i e x Mat All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...All manuals and user guides at all guides com...

Page 3: ...OSITIONING OUTWARD SWING PEDESTAL POSITIONING WALL MOUNT PEDESTAL ELECTRICAL CONNECTIONS COMMISSIONING COLLISION SENSING ADJUSTMENT SIMPLIFIED PEDESTAL MOUNTING POSITION Page 2 Page 2 Page 3 Page 3 Pa...

Page 4: ...NICS ENCLOSURES FASTENERS PEDESTALS BATTERIES M10 x 20 SET SCREW M8 x 40 SET SCREW WALL MOUNT PEDESTAL SHORT PEDESTAL STANDARD PEDESTAL M12 CAP SCREW M8 NYLOC NUTS M8 FLAT WASHER PADLOCK 35AH BATTERY...

Page 5: ...LENGTHS AVAILABLE See page 11 Fig 2 ABSOLUTE MINIMUM FOR A IS 220mm FOR AUTO MATE 260mm FOR MAXI MATE 250mm 400mm 500mm FOR Standard Maxi Mate or single Auto Mate kits FOR Standard double Auto Mate ki...

Page 6: ...MOTOR LIMIT SWITCH EITHER 220V AC SUPPLY CABLE OR 15V AC TRANSFORMER SECONDARY INTERCOM IN HOUSE STATUS SIGNALLING INTERCOM CONTROL BOX TO GOOSENECK PILLAR LIGHTS REMOTE RECEIVER PEDESTRIAN KEYSWITCH...

Page 7: ...n millimetres 2 All dimensions referenced to hinge point 3 Gate thickness assumed to be 40mm 4 Distance depends on pillar size Check carefully before installation NOTES O GATE OPEN ANGLE 110 ARM LENGT...

Page 8: ...S Standard Pedestal Positioning Gate Inward Opening 6 6 See Page 14 for Wall Mount Pedestals M Mounting Control Box All manuals and user guides at all guides com...

Page 9: ...UP GATE OPENING ANGLE AND DIMENSION C FOR SIZE OF DRIVE ARM SUPPLIED See Table Overleaf STEP 2 SWING GATE TO DESIRED OPEN POSITION 70 120 DEGREES MAKE SECOND MARK S2 ON THE GROUND e g SAY Z IS MEASURE...

Page 10: ...522 518 515 511 508 504 501 498 494 491 488 485 482 480 477 474 472 469 467 464 462 872 861 851 841 831 821 812 803 795 786 778 770 762 755 747 740 733 726 720 713 707 701 695 689 684 678 673 668 663...

Page 11: ...ON GROUND GATE CLOSED WELD OR BOLT BRACKET TO GATE POSITION GATE BRACKET AT DIMENSION C STEP 5 MAKE MARK S5 ON GROUND SWING GATE TO OPEN POSITION SAME POSITION AS STEP 2 DRAW SETUP LINE THROUGH S4 S5...

Page 12: ...ET SETUP LINE DRIVE ARM S5 PEDESTALS CAN BE MOUNTED ANYWHERE ALONG A LINE 60mm AWAY FROM SETUP LINE TOWARDS THE PILLAR STEP 6 RECOMMENDED LOCATION OF PEDESTAL LIE DRIVE ARM OVER SETUP LINE SUCH THAT E...

Page 13: ...ON FOR CORRECT POSITION OF PEDESTAL PLAN VIEW OF GEARBOX PEDESTAL POSITIONING NOTE THIS SHOWS AN ALTERNATIVE POSITION OF THE PEDESTAL IF SPACE IS LIMITED NOTE ALTERNATIVE POSITION WHEN THERE IS ABSOLU...

Page 14: ...M10 x 20 BOLTS MOUNT GEARBOX ONTO PEDESTAL AND BOLT INTO PLACE 108 120mm CONCRETE BEND OUT TABS CONDUIT FOR MOTOR LIMIT SWITCH CABLES 500mm MIN 300mm MIN Standard Pedestal Positioning cont d DIG HOLE...

Page 15: ...o THE CORRECT ARC FOR LHS DRIVE ARM THE CORRECT ARC FOR RHS DRIVE ARM CONNECTING ARM ADAPTOR PIECE BALL JOINT LOCK NUT DRIVE ARM MOTOR 13 13 STEP 12 ALIGN GATE END POINTS LOCK ADAPTOR PIECE TO BALL J...

Page 16: ...REMAINS INSIDE PROPERTY 250mm DRIVE ARM MUST BE USED LONG CONNECTING ARM REQUIRED DRIVE ARM SHOWN IN GATE CLOSED POSITION 14 14 STEP 4 AFFIX GATE BRACKET TO GATE USING DIMENSION C FROM HINGE CENTRE L...

Page 17: ...t d 15 15 GATE SHOWN OPEN HORIZONTAL LINE L1 100mm STEP 6 MARK HORIZONTAL LINE SHOWN ON PILLAR 100mm BELOW TOP OF GATE BRACKET STEP 5 MARK POINT S5 ON THE GROUND USING A PLUMB BOB Marking Set up Line...

Page 18: ...ACKET LEFT OR RIGHT ALONG LINE L1 UNTIL PLUM BOB IS 60mm BACK FROM SETUP LINE STEP 7 90 L1 L1 o USE M12 RAWLBOLTS 97mm 74 5mm 60mm PLUMB BOB 59mm L1 T N SE UP LI E S4 S5 X X X X Wall Mount Pedestal co...

Page 19: ...10 BOLT GEARBOX IN PLACE LOOSELY FIT DRIVE ARM TO OUTPUT SHAFT CUT CONNECTING ARM TO FIT INSIDE ADAPTOR PIECE DEEPER THAN FIXING HOLE CONTROL BOX STEP 9 BOLT PEDESTAL ADAPTOR ON TO WALL BRACKET BOLT P...

Page 20: ...OID STRIKE 15V AC SUPPLY 15V AC SUPPLY AUTO CLOSE CONTROL FREE EXIT LOOP HOLIDAY LOCKOUT SLAVE MOTOR BATTERY MASTER MOTOR SIGNAL COMMONS NEG PILLAR LIGHT CONTACT Potential Free 1 2 3 4 5 6 7 8 9 10 11...

Page 21: ...HING DETAILS REFER TO PAGE 26 2 CONTROLLER MODEL MOTOR FUSE RATING AUTO MATE MAXI MATE 8A Slow Blow 16A Slow Blow 0 2mm CABLE 12 1 CONTROLLER MODEL RECEIVER FOR DETAILS OF SETTING CODE SWITCHES REFER...

Page 22: ...ROLLER MODEL CP77 CP87 C 2 3 3 NEG TRG INTERCOM CONNECTIONS NOTE SOLENOID LOCK OR MAGNET IS USED TYPICALLY ON SINGLE SWING GATES OPTION 1 SOLENOID LOCK MAGNETIC LOCK OR OPTION 2 0 5mm CABLE 2 CONTROLL...

Page 23: ...P87 CP87 12V NEG N O INFRA RED BEAMS PEDESTRIAN KEYSWITCH 21 21 SPRING RETURN SWITCH NEG PED BEAM N O 12V LINK NOTE TYPICAL SAFETY BEAM IS SHOWN REFER TO MANUFACTURER FOR DETAILS NOTE THE INFRA RED BE...

Page 24: ...A N A N A 2 C CP87 CP87 HOLIDAY LOCKOUT OR OR FREE EXIT LOOP 22 22 CONTROL BOX UNDERGROUND LOOP PUSHBUTTON KEYPAD 1 4 7 8 9 5 6 2 3 12V NEG COM N O NEG LOCK LATCH TYPE RADIO RECEIVER RELAY MUST HAVE L...

Page 25: ...E SWITCH 23 23 A C NEG SIGNAL COMMON 0 2mm CABLE CONTROLLER MODEL CP77 CP87 7 N A C N A NEG LED FITTED TO HANDSET BASE SEPARATELY STATUS LED ANODE CATHODE GATE STATUS LED INDICATION BATTERY LOW 3 FLAS...

Page 26: ...0 5mm NORSK CABLE OR S W A 2 2 E N L CONTROLLER MODEL CONTROLLER MODEL CP77 CP77 220V AC SUPPLY OR OTHER VOLTAGE TO SUIT TYPE OF GLOBES USED AUTOCLOSE TOGGLE C A 6 B N A N A N A N A CP87 CP87 PILLAR L...

Page 27: ...TROLLER MODEL CP77 CP87 15 8 16 9 CONTROLLER MODEL NOTE CP77 CONTROLLER CARD MUST BE MODIFIED FOR PSU SUPPLY REFERENCE CP77PSU CP77PSU CP87 15 F N A N A 16 G N A N A AC AC AC AC 220V AC PLUG IN OR ENC...

Page 28: ...ONTROL CARD SCREEN OF INTERCOM CABLE EARTH SCREEN AT HOUSE AS WELL EARTH ROD TO ESCOM EARTH SOLAR PANEL TO SECOND SOLAR PANEL IF FITTED NOTE 2 NOTE 2 TO MOTOR LOAD e g FLUORESCENT LIGHT 12V DC e g PDI...

Page 29: ...S NOT APPLY TO CP87 CONTROL CARD MAINS FAILURE BATTERY LOW OPENING CLOSING GATE OPEN AUTOCLOSE TIMER COLLISION SENSITIVITY CONTROL CARD SETUP NOTE LIMIT SWITCH LEDS ONLY ON VERSION 1 1 CARDS AND ABOVE...

Page 30: ...ER SUPPLY CONNECTED AND SWITCHED ON x x CP77 CP87 CONTROLLER GREEN POWER SUPPLY CONNECTED AND SWITCHED ON L N E L N E 220V AC SUPPLY PLUG IN CONNECTOR CP13E POWER SUPPLY 4mm CABLE 2 CONTROLLER MODEL C...

Page 31: ...ARE FIG 1 AND FIG 2 BELOW SWOP MOTOR WIRES TO GIVE CORRECT MOTOR ROTATION IF NECESSARY SEE FIG 3a BELOW TEST THAT MOTOR STOPS WHEN IT HITS THE LIMIT SWITCH SWOP LIMIT SWITCH WIRES IF MOTOR DOES NOT ST...

Page 32: ...R ARM CAUSES GATE TO STOP THEN DISCONNECT L S COMMON SEE FIG 2 BELOW AND ALLOW MOTOR TO DRIVE PAST LIMIT SWITCH SPRING WHEN L S STRIKER ARM IS CLEAR RECONNECT WIRE L S O P E N L S C L O S E D S M O N...

Page 33: ...IVE ARM DESCRIBES 180 DEGREE ARC NOTE L H S MOTOR SHOWN 31 31 DRIVE ARM POSITION WITH GATE CLOSED DRIVE ARM POSITION FOR GATE FULLY OPEN 180 ARC O DIRECTION OF ROTATION FOR L H S TO OPEN ADJUST ADJUST...

Page 34: ...OTOR STOPS DOES NOT REVERSE ON HITTING AN OBSTRUCTION OPENING CLOSING SETS SENSITIVITY FOR MASTER AND SLAVE GATE WHILE ADJUST SETTING S ON CONTROL CARD SEE FIGURE 2 SUCH THAT GATE S WILL OPEN AND CLOS...

Page 35: ...All manuals and user guides at all guides com...

Page 36: ...l 250 334 1553 ABA GATES WESTERN AUSTRALIA Tel 8 933 03061 DOMINATOR SYSTEMS NEW ZEALAND Tel 3 384 5145 ICBT VICTORIA Tel 3 933 54213 ROTECH QUEENSLAND Tel 7 326 47330 SA GATES SOUTHERN AUSTRALIA Tel...

Reviews: