SWITCH NO
3
4
DESCRIPTION OF OPERATION (MODE)
GREEN POWER ON LED
(ON WITH MAINS POWER PRESENT)
GATE STATUS
LED (RED)
SINGLE MOTOR SYSTEM WITHOUT AUTOCLOSE
SINGLE MOTOR SYSTEM WITH AUTOCLOSE
DOUBLE MOTOR SYSTEM WITHOUT AUTOCLOSE
DOUBLE MOTOR SYSTEM WITH AUTOCLOSE
CONDOMINIUM MODE (SINGLE MOTOR)
PIRAC MODE (SINGLE MOTOR)
CONDOMINIUM MODE (DOUBLE MOTOR)
PIRAC MODE (DOUBLE MOTOR)
LINEAR MOTOR(S) WITHOUT AUTOCLOSE
LINEAR MOTOR(S) WITH AUTOCLOSE
5 SECS
OPEN
45 SECS
CLOSE
LED
GATE STATUS
CP77 AND CP87
GATE CLOSED
LED OFF
LED ON
FAST FLASH
SLOW FLASH
2 FLASH/2 SECS
3 FLASH/2 SECS
NOTE: MAINS FAILURE DOES NOT
APPLY TO CP87 CONTROL CARD.
MAINS FAILURE
BATTERY LOW
OPENING
CLOSING
GATE OPEN
AUTOCLOSE TIMER
COLLISION SENSITIVITY
CONTROL CARD SETUP
NOTE: LIMIT SWITCH LEDS ONLY ON VERSION 1.1 CARDS AND ABOVE
(SEE NOTE)
x
x
x
x
x x
x x
x x
x
C
P
7
7
V
1
.X
CP87
AUTOCLOSE
SELECT
GATE STATUS
LED (RED)
X
X
1
9
COLLISION SENSITIVITY
MIN
MAX
AUTOCLOSE
"OFF"
AUTOCLOSE
"ON"
x
GREEN POWER ON LED
(ON WITH MAINS
POWER PRESENT)
- IDENTIFY STATUS LED WHICH WILL GIVE INFORMATION ON GATE STATUS (e.g. WHETHER GATE SHOULD BE OPEN OR CLOSED).
- SELECT DIP SWITCH SETTINGS TO GIVE REQUIRED MODE OF OPERATION (CP77 ONLY).
- SELECT "AUTOCLOSE" IF REQUIRED (e.g. USING SW1 ON CP77, JUMPER ON CP87).
- SET AUTOCLOSE TIMER POTENTIOMETERS TO MINIMUM INITIALLY AND ADJUST TIME TO SUIT AFTER COMMISSIONING.
- SET COLLISION SENSITIVITY POTENTIOMETERS TO MID POSITION (SEE PAGE 32 FOR CORRECT FINAL ADJUSTMENT).
COMMISSIONING INSTRUCTIONS