SCENIC W504 User Manual
Eng
Users can select the desired mode by pressing MENU button until they reach the
“FAN-” page. Press ENTER; you see the current value. Then press UP or DOWN to
choose from FAN0 to FAN2. Press ENTER to confirm and MENU to go back to the
selection of menu pages.
FAN0
keeps the fan off when LED temperature is below 40°C (104°F). It comes into
operation form 41°C (105°F ca.), and the DSP increases fan speed according to LED
board temperature. Heat protection limit is fixed at 90°C; in normal conditions, this
limit is never exceeded, as fan would act to cool the chip. Maximum noise @ 1m
(max. fan speed) is 43dBA ca.
FAN1
(Silent Mode) always switches the fan off. Internal DSP controls the LED tem-
perature and adjusts its brightness to keep the chip always cooled. Brightness re-
duction starts from 41°C (0% reduction) to 87°C (45% reduction). Fan noise is 0dBA.
FAN2
preset keeps the fan always working, so the LED board temperature will al-
ways be kept cooled. Fan noise @ 1m is 43dBA ca.
6.4. Master/Slave Mode
In case you need to control more SCENIC W504 simultaneously (all fixtures operate
exactly the same way) without the use of a DMX controller, you can use the Master/
Slave function. There is no specific function to be activated on the display; simply
the master unit must be connected first, all the others in daisy-chain through the
DMX IN-OUT connections. All units (master and slaves) should be in
DMX Channel
001 only
, and have same Channel Mode (all 6CH or 2CH).
7 - T
roubleshooTing
Problem
Probable Cause(s)
Remedy
No response from fixture
when power is applies
No power to fixture
Check power cables
Check mains plug
Fixture does not reset
correctly
Electronic failure
Contact service technician*
No light, LED cuts out
intermittently, or burns out
too quickly
LED missing or blown
Disconnect fixture and replace
the LED
Fixture or LED is too hot
Allow fixture to cool. If prob-
lem persists, contact service
technician*
Fixture resets but does
not respond correctly to
controller (DMX mode
operation)
Controller not connected
Connect controller
Incorrect addressing of the
fixtures
Check address setting on fixture
and controller
Bad data link connection
Inspect cables and correct poor
connections and/or broken
cables.