6.7. Master/Slave Mode
In case you need to control more SCENIC 100W WW-CW simultaneously (all fixtures
operate exactly the same way) without the use of a DMX controller, you can use the
Master/Slave function. There is no specific function to be activated on the display;
simply the master unit must be connected first, all the others in daisy-chain through
the DMX IN-OUT connections. All units should be in the same channel mode 5ch or
2ch, and DMX channel has to be the same.
7 - T
roubleshooTing
Problem
Probable Cause(s)
Remedy
No response from fixture
when power is applies
No power to fixture
Check power cables
Check mains plug
Fixture does not reset
correctly
Electronic failure
Contact service technician*
No light, LED cuts out
intermittently, or burns out
too quickly
LED missing or blown
Disconnect fixture and replace
the LED
Fixture or LED is too hot
Allow fixture to cool. If prob-
lem persists, contact service
technician*
Fixture resets but does
not respond correctly to
controller (DMX mode
operation)
Controller not connected
Connect controller
Incorrect addressing of the
fixtures
Check address setting on fixture
and controller
Bad data link connection
Inspect cables and correct poor
connections and/or broken
cables.
Conflict between tracking
and vector control
Eliminate scene cross-fade on
controller
Data link not terminated
Insert termination plug in output
of last fixture**
Defective fixture or 2 devices
transmitting on link
Bypass fixtures one at a time
until normal operation is
regained: unplug both connec-
tors and connect them directly
together