background image

9

9

SCENIC 100W WW-CW User Manual

Eng

5 -  P

roDuCT

 s

eTuP

DISPLAY

MENU

UP DOWN ENTER

DMX OUT

DMX IN

1

2

4

3

5.1. Rear Panel Description

The operation panel includes the LED display and control button operation area.

1)  4 Digit LED Display

It shows the operating mode and other system information.

2)  Control Buttons

MENU Button

 - Short-press it to switch the setting pages.

UP Button

 - It scrolls up individual items in the selection menu and sub-menus for 

system settings (DMX address, Operation Mode, etc.), and increases values/settings 

of parameters.

DOWN Button

 - It scrolls down individual items in the selection menu and sub-

menus for system settings (DMX address, Operation Mode, etc.), and increases 

values/settings of parameters.

ENTER Button

 - Press ENTER to access menu levels and confirm parameter value 

changes.

3)  Power and Wiring

 

y

Always make sure that the voltage of the outlet to which you are connecting 

the product is within the range stated in paragraph “8 - Specification” on page 

16 or rear panel of the product (AC110V-240V 50/60Hz).

Summary of Contents for SCENIC 100W WW-CW

Page 1: ...care of it Leggete questo manuale e conservatelo per future consultazioni User Manual Manuale Utente 1x100W COB Warm White Pure White LED Studio Projector Proiettore da Studio con 1x LED COB da 100W...

Page 2: ...ever closer to professional s real requirements The CENTOLIGHT Team Gentile Cliente Grazie per aver scelto un prodotto CENTOLIGHT La nostra missione quella di soddisfare ogni possibile richiesta da p...

Page 3: ...tures 8 4 2 Product Overview 8 4 3 Product Dimensions 8 5 Product Setup 9 5 1 Rear Panel Description 9 5 2 DMX Terminator 11 5 3 3 Pin vs 5 Pin DMX cables 11 6 Menu Operation 11 6 1 Set DMX Address 12...

Page 4: ...roduct and included accessories appear damaged from shipping or show signs of mishandling notify the carrier or dealer seller imme diately In addition keep the box and contents for inspection If the f...

Page 5: ...conditions which may be sufficient to constitute the risk of electric shock or death The symbol is used to describe important installation or config uration problems Not following advice and informat...

Page 6: ...ure and the machine s technical installation is approved by an expert before taking into operation for the first time and after changes before taking into operation an ther time He has also to make su...

Page 7: ...in the man ual Refer all servicing to qualified service personnel only The internal compo nents of the equipment must be purchased from the manufacturer Only use accessories attachments or parts reco...

Page 8: ...endent LED chips y Fresnel lens and adjustable Barn doors for up to 60 angle y Fan speed controlled by temperature y Advanced dimmer system with several curves y Extremely lightweight only 4lbs 1 81kg...

Page 9: ...selection menu and sub menus for system settings DMX address Operation Mode etc and increases values settings of parameters DOWN Button It scrolls down individual items in the selection menu and sub m...

Page 10: ...DMX control signal to another spark machine or other DMX device DMX machines are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture con...

Page 11: ...ry signal cable can transmits signals to 20 unit fixtures at most Signal amplifier is a must to connect more fixtures 5 3 3 Pin vs 5 Pin DMX cables DMX connection protocols used by controllers and fix...

Page 12: ...urable address to 511 or 508 to have all channels controllable Set the SCENIC 100W WW CW starting address in the 001 508 DMX range to enable control of up to 102 products in the 5 channel control mode...

Page 13: ...and warm white The intensity of each channel is adjust able from 0 to 255 1 Pure White Adjustment To set the intensity of pure white press MENU button until you reach n page Press ENTER you see the c...

Page 14: ...irm and menu to go back to the selection of menu pages 6 6 Dimmer Curves SCENIC 100W WW CW offers 5 dimmer curves Normal 4 Curves with different times for T up and T down see the picture below and the...

Page 15: ...ut too quickly LED missing or blown Disconnect fixture and replace the LED Fixture or LED is too hot Allow fixture to cool If prob lem persists contact service technician Fixture resets but does not r...

Page 16: ...F Fan in action with threshold at 58 60 C 136 140 F Fan Noise 0dB under 58 C 136 F 44 0 dBA 0 5m above 58 C 136 F 46 1 dBA close to fixture above 58 C 136 F IP Rate IP20 Working Temperature 20 C to 50...

Page 17: ...s CENTOLIGHT SCENIC 100W WW CW Description LED PAR conform to the essential requirements of European Low Voltage Directive 2014 35 EU European EMC Directive 2014 30 EU comply with the following standa...

Page 18: ...CENTER Via Enzo Ferrari 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA num ber Shipping charges have to be covered by the owner of the product For further...

Page 19: ...24 4 3 Dimensioni del Prodotto 24 5 Setup del prodotto 25 5 1 Descrizione del pannello posteriore 25 5 2 Connessioni DMX 26 5 3 Terminatore DMX 27 5 4 Cavi DMX 3 Poli 5 Poli 27 6 Funzionamento dei Me...

Page 20: ...giati dalla spedizione o mostrano segni di maltrattamento avvisare immediata mente il vettore o il rivenditore Inoltre conservare la scatola e il contenuto per una eventuale ispezione Se l apparecchi...

Page 21: ...tensione anche in condizioni operative normali che possono essere suffi cienti a costituire il rischio di scosse elettriche o morte Questo simbolo usato per descrivere importanti problemi di installaz...

Page 22: ...lta il funzionamento dopo aver apportato qualsiasi modifica Deve inoltre assicurarsi che un esperto approvi nuovamente l installazione e i dispositivi di sicurezza ogni anno IMPORTANTE il montaggio su...

Page 23: ...e dal produttore 4 Introduzione CentoLight SCENIC 100W WW CW un PAR a LED compatto e leggero per uso indoor La sorgente luminosa costituita da un LED da 100W con tecnologia COB che oltre ad aumentare...

Page 24: ...llata dalla temperatura y Sistema dimmer avanzato con differenti curve y Molto leggero solo 1 8kg 4 2 Panoramica del Prodotto Bracket Adjustment knob Barndoor Fresnel Lens 4 3 Dimensioni del Prodotto...

Page 25: ...i vari menu e i parametri dei menu indirizzo DMX modalit operativa ecc Aumenta i valori Impostazioni dei parametri Tasto Gi Premere per scorrere i vari menu e i parametri dei menu indirizzo DMX modal...

Page 26: ...evere dati attraverso una catena seriale a cascata Questo tipo di connessione permette di connettere il DMX OUT di un dispositivo al DMX IN del dispositivo successivo L ordine in cui i dispositivi son...

Page 27: ...legare pi apparecchi 5 4 Cavi DMX 3 Poli 5 Poli I protocolli di connessione DMX utilizzati dai produttori di centraline teste mobilie e fari non sono standardizzati in tutto il mondo Tuttavia due sono...

Page 28: ...08 DMX per abilitare il controllo fino a 102 prodotti nella modalit di controllo a 5 canali Impostare l indirizzo di partenza SCNIC 100W WW CW nella gamma 001 511 DMX per abilitare il controllo fino a...

Page 29: ...L intensit di ciascun canale regolabile da 0 a 255 1 Regolazione del Bianco Puro Per impostare l intensit del bianco puro premere il tasto MENU fino a raggiunge re la pagina n Premere ENTER si vede il...

Page 30: ...confermare e MENU per tornare alla selezione delle pagine dei menu 6 6 Curve dimmer SCENIC 100W WW CW offre 5 curve di Dimmer normale 4 curve con tempi diversi per T Up e T Down vedere l immagine qui...

Page 31: ...sso or bruciato Scollegare il faro e sostituire il LED Il faro o il LED sono molto caldi Fate raffreddare il faro Se il problema persiste contattate il servizio assistenza L apparecchio si accende ma...

Page 32: ...104 F Ventola in azione con soglia a 58 60 C 136 140 F Rumore Ventola 0dB sotto 58 C 136 F 44 0 dBA 0 5m sopra 58 C 136 F 46 1 dBA vicino al faro sopra 58 C 136 F Grado di Protezione IP IP20 Temperatu...

Page 33: ...els CENTOLIGHT SCENIC 100W WW CW Description LED PAR conform to the essential requirements of European Low Voltage Directive 2014 35 EU European EMC Directive 2014 30 EU comply with the following stan...

Page 34: ...0 62017 Porto Recanati Italia Per inviare un prodotto al centro di assistenza necessario un numero di RMA Le spese di trasporto devono essere coperte dal proprietario del prodotto Per ulteriori inform...

Page 35: ...otto viene importato nella UE da FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy www centolight com CentoLight is a registered trademark of FRENEXPORT SPA Italy CentoLight un marchio di...

Page 36: ...Ver 1 0 Mar 2021 www centolight com...