Assembly and operating instructions
CENTAX-TT
024T-00130…00460
M024-00001-EN
Rev. 6
CENTA Antriebe Kirschey GmbH
51 / 54
WARNING
Injuries and material damages can occur by:
Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.
IMPORTANT
We recommend the following mounting fluids:
For mounting:
Oil with a viscosity 300 mm
2
/s at 20°C, e.g. SKF LHMF300
For dismantling:
Oil with a viscosity 900 mm
2
/s at 20°C, e.g. SKF LHDF900
Remove the screw plug (19) from the hub (2).
Connect the pump (
p
max
= 3000 bar
) to the thread (c) of the hub (2) to
expand the hub.
Screw the pump to the shaft (A), in order to hold the hub.
Repeat the following mounting section, until the hub is completely released
from the shaft:
Build up oil pressure in order to hold the hub.
Build up oil pressure to expand the hub (
p
max
= 2000 bar
).
Slowly reduce the oil pressure for holding the hub.
Reduce the oil pressure for expanding the hub.
Remove the pump for holding the hub from the shaft (A).
Remove the pump for expanding the hub from the hub (2).
Turn the hub (2), drain oil out of the thread (c) and dispose correctly.
Screw the screw plug (19) into the hub (2).
Remove the hub (2) from the shaft (A).
9.7.3
Dismantling the adapter
See Fig. 6-3:
Loosen and remove the screws of the connection adapter (2) and flange (C).
Pull the adapter (2) off/out of the centring of the flange (C) and remove.
9.8
Reassembling the coupling
Reassemble the coupling as described in chapter 6.