9.5
Dismantling the adapter (6) from the flywheel (type FS; if
necessary)
See Fig. 6-5:
Loosen the screw (30) of the connection adapter (6) and flywheel (B) and
remove.
Pull the adapter (6) out of the centring of the flywheel (B) and remove.
9.6
Dismantling the adapter (3; if necessary)
See Fig. 6-4 and 6-3:
Loosen and remove the screws (4) of the connection adapter (3) and
hub/adapter (2).
Pull the adapter (3) from the centring of the hub/adapter (2) and remove.
9.7
Dismantling the hub/adapter (2; if necessary)
Dismantle the hub/adapter (2) as appropriate for the supplied design (see
installation drawing):
Dismantling the hub with cylindrical bore and keyway, see chapter 9.7.1
Dismantling the hub with cylindrical bore and keyway, see chapter 9.7.2
Dismantling the adapter (2), see chapter 9.7.3
9.7.1
Dismantling the hub with cylindrical bore and keyway
See Fig. 6-1:
Remove the hub (2) from the shaft (A).
9.7.2
Dismantling the hub with conical oil interference fit
See Fig. 6-2:
WARNING
Injury and material damage can occur as a result of:
Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.
WARNING
Injury and material damage can occur as a result of:
Hydraulic fluid spraying out
Use protective goggles.