Assembly and operating instructions
CENTAX-TT
024T-00130…00460
M024-00001-EN
Rev. 6
CENTA Antriebe Kirschey GmbH
28 / 54
6.3.2
Mounting the adapter of coupling size 440-460
Fig. 6-5 Mounting the adapter of coupling size 440-460
Item
Info
Designation
Remark
2
Hub/Adapter
illustrated is the hub (2)
3
Adapter
4
Screw ISO4762-10.9
Push the adapter (3) onto the centring of the hub/adapter (2).
Alternating:
Screw the adapter (3) to the hub/adapter (2) using the screws (4).
Screw the hub/adapter (2) to the adapter (3) using the screws (4).
6.4
Aligning the units
Align the units to be connected (see chapter 5).