Turntable does not turn
Lack of power supply.
➥
Check mains voltage presence.
➥
Check the state of fuses.
➥
Check the state of the differential and/or magneto-thermal circuit breaker.
➥
Check cable connections in the plug.
The motor is not running.
➥
Check the microswitches of the pedal unit (only for motor inverter)
➥
Check the motor rotation control of the pedal unit
➥
Replace the inverter board (only for motor inverter).
➥
Replace the motor.
Belt broken.
➥
Replace the belt.
Reduction gear clamped:
➥
Replace the reduction gear
Turntable does not rotate in either direction
Control faulty.
➥
Replace the inverter.
➥
Check the microswitches of the pedal unit (only for motor inverter)
➥
Replace the inverter board (only for motor inverter). Reduction gear clamped.
➥
Replace the reduction gear.
Gear unit noisy. The turntable makes a 1/3 of a turn and
then stops
Reduction gear is seizing.
➥
Replace the reduction gear.
Turntable stops under strain, but the motor is running
Insufficient belt tension.
➥
Adjust belt tension or replace it.
Summary of Contents for SM675TI
Page 15: ...User s manual 15 EN 01 05 02 18 03 04 21 08 06 07 10 11 20 22 12 14 15 16 16 17 19...
Page 69: ...Note...
Page 83: ...Manuel d utilisation 83 FR 01 05 02 18 03 04 21 08 06 07 10 11 20 22 12 14 15 16 16 17 19...
Page 137: ...Note...
Page 151: ...Manual de uso 151 ES 01 05 02 18 03 04 21 08 06 07 10 11 20 22 12 14 15 16 16 17 19...
Page 205: ...Note...
Page 206: ...Note...
Page 207: ......