background image

 

Cable voltage check     5V to 16V DC 

4.MEASURING PROCEDURE 

4.1 Transmitter&Receiver operation 

1).At one end of the cable, Connect one of the transmitter 
terminals marked “CH1 to CH16”to each core of the cable 
under tester.Connect the “COM”reference lead (black 
alligator) of the transmitter to a core which is the only known 
one. 

 

2).At the other end of the cable ,connect the “COM 
terminal”(black alligator) of the receiver. 
When the “input terminal”(red alligator) of the receiver is 
successively touched on the cores of the cable under test,the 
relevant number of the way is indicated on the display of the 
receiver(1-16). 

Operation example 1: Cable trace test 
Operation example 2: Metal water pipe trace test 
                                                       
 
CAUTION: Though the units already build in the 
protection

 

circuit,however do not apply voltage that over 

50V(AC or DCV)toany alligator clips of 
transmitter&receiver. Otherwise the instruments may 
defect permanently.  

 

4.2 Beep alarm test : “

TEST”button to down use receiver of 

2Croc clips connect cable of  two port if cable is put through 
will have beep sound.otherwise cable isn’t put through or isn’t 
same a cable. 

CAUTION: Beep if less than 100

Ω 

 

Summary of Contents for LA-1015

Page 1: ...CABLE TESTER DIGITAL MULTIMETER Cable Identifier DMM User s Guide OP ON CABLE TESTER CABLEIDENTIFIER CABLE TESTER CABLEIDENTIFIER Vcheck...

Page 2: ...2 2 Receiver Description 4 2 3 Digital Multimeter Description 4 3 SPECIFICTIONS TETHNICAL DATA 4 3 1DMM 4 5 3 2Transmitter 6 3 3 Receiver 6 4 MEASURING PROCEDURE 7 4 1 Transmitter Receiver operation...

Page 3: ...cores at either end of a multi core cable With the remote kit it can tester cables installed far away either on wall plate or patch panel Digital multimeter function make it easy to measure DC AC vol...

Page 4: ...4 3 SPECIFICTIONS TETHNICAL DATA 3 1 DMM...

Page 5: ...200 0 0 8 rdg 5d 2 000k 20 00k 200 0k 1 2 rdg 3d 2 000M 2 0 rdg 5d 20 00M 5 0 rdg 8d Max input voltage 600V AC DC Diode Test Test current 1mA max open circuit voltage of 1 5V typical Continuity Check...

Page 6: ...600V Pollution degree II CE Approved 3 2 Transmitter Display Two red LED lamps Aligators 17Croc clips red 16 black 1 Cable resistance 30K Ohm max Power 9V battery Power current 1 8mA Operating temper...

Page 7: ...is successively touched on the cores of the cable under test the relevant number of the way is indicated on the display of the receiver 1 16 Operation example 1 Cable trace test Operation example 2 Me...

Page 8: ...o the negative COM terminal and the red test lead into the positive V terminal 2 Set the function switch to VAC or VDC position 3 Connect the test leads in parallel to the circuit under test 4 Read th...

Page 9: ...uch the red test probe tip to the positive side of the circuit 7 Apply power to the circuit 8 Read the current in the display RESISTANCE MEASUREMENT 1 Set the function switch to the position 2 Insert...

Page 10: ...egative COM terminal and the red test lead into the positive terminal 4 Touch the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately 150 the audibl...

Page 11: ...tton The meter reading will not change as readings change 2 Press the MAX hold button again to return to normal operation Hold Button The Data Hold function allows the meter to freeze a measurement fo...

Page 12: ...of the proper size and value 0 2A 250V fast blow for the 200mA range 8 Align the center board with the connectors and gently press into place 9 Replace and secure the rear cover battery and battery c...

Page 13: ...13 2 Remove the bottom cover and secure the screw 3 Replace old battery with fresh two 1 5V AAA or 9V type batery 4 Replace the bottom cover and secure the screw...