3.Functional Description
The LCR meter could measure Inductance/Capacitance/
Resistance with secondary parameters including dissipation factor
(D), quality factor(Q), phase angle(θ), equivalent series/parallel
resistance(ESR or Rp). The meter is fully auto ranging operation
for AC impedance & DC resistance measurement. It means the
user could measure the L/C/R components directly at AUTOLCR
smart mode without changing the function key. User could also
select the target test frequencies of 100Hz/120Hz/1kHz/10kHz
/100kHz depending on DUT(device under test) type. Components
could be measured in series or parallel mode according to the DUT
impedance automatically.
Dual LCD display
Auto LCR smart check and measurement
Series/Parallel modes are selectable
Ls/Lp/Cs/Cp with D/Q/
3-1 Introduction
Features
3-2
•
•
•
•
•
•
•
•
•
•
•
θ/ESR parameters
Support DCR mode 200.00Ω~200.0MΩ
Five different test frequency are available: 100/120/1k/10k/
100k Hz
est AC signal level: 0.6mVRMS typ.
Test range: (ex. F=1kHz)
200.00 μH ~ 2000.0 H
2000.0 pF ~ 2.000 mF
20.000 Ω ~ 200.0 MΩ
Multi-level battery voltage detector
Support Backlight & Buzzer sound driver
Primary Parameters Display:
DCR:DC Resistance
Ls:Serial Inductance
Lp:Parallel Inductance
Cs:Serial Capacitance
Cp:Parallel Capacitance
T
L:
C:
R:
5