background image

Coating Thickness Tester User Manual

 Reorient or relocate the receiving antenna.

 Increase the separation between the equipment and receiver.

  Connect the equipment into an outlet on a circuit different from

  that to which the receiver is connected.

  Consult the dealer or an experienced radio/TV technician for help. 

 This device complies with Part 15 of the FCC Rules. Operation is subject
 to the following two conditions :
(1) this device may not cause harmful interference, 

and

(2) this device must accept any interference received, including 
      interference that may cause undesired operation.

Shielded cables must be used with this unit to ensure compliance 
with the Class B FCC limits.

The device must not be co-located or operating in conjunction with
any other antenna or transmitter.

Rev

.181112

Summary of Contents for DT-157

Page 1: ...Coating Thickness Tester User Manual Group4 FE DEL 44 Group4 FE DEL 44...

Page 2: ...nu System and Basic Settings 1 3 Settings 3 1 Unit Setting 1 3 2 Backlight Setting 1 3 3 Auto Power Off 1 3 4 Turn on off Bluetooth 1 3 5 Adjust gray scale contrast 1 4 System Information 4 1 System v...

Page 3: ...type of probe via MENU system or it will work automatically Features Measured Coatings Non magnetic coatings e g paint zinc on steel Insulating coatings e g paint anodizing coatings on no ferrous met...

Page 4: ...be used on special geometries or on materials with special properties 1 2 Description of the Gauge For measurement on steel substrates the gauge works on the magnetic induction principle for measureme...

Page 5: ...umidity F Magnetic induction 0 2000 m 0 78 7mils 0 1000 um 2 2um 1000 2000 um 3 5 0 39 3mils 2 0 08 mils 39 3 78 7mils 3 5 0 100um 0 1um 100um 1000um 1um 1000um 2000um 0 01mm 0 10mils 0 01 mils 10 78...

Page 6: ...lection or working mode switch 7 Probe 8 Lanyard hole 9 Battery cover 1 7 LCD Display 1 Working mode 2 Auto measure mode 3 Bluetooth indication 4 Ferrous or No ferrous metals being measured 9 It will...

Page 7: ...Insert new battery Close the battery cover Caution Make sure the anode and cathode are correctly positioned 2 3 Menu System and Basic Settings Press to power on the gauge will work in measuring mode...

Page 8: ...on to enter working mode Press up down button to select working mode Press left button for OK 3 Settings 3 1 Unit Setting 3 1 1 Select unit Press left button to enter the menu Press up down button to...

Page 9: ...Bluetooth You can also download measured data via software by PC or phone or other Bluetooth receiving device in working mode Note Turn on Bluetooth battery power will loss quickly please do not turn...

Page 10: ...on to select gray scale Press left button to enter Press up down button to adjust gray scale Press left button for ok 4 System Information 4 1 System version number and gauge serial number display Pre...

Page 11: ...ress left button to enter Press right button to return the measurement interface Measure directly on Fe or Non Fe matrix can measure many times last measure is effective Press left button to confirm t...

Page 12: ...e fault Err5 Non Fe probe fault Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NO...

Page 13: ...technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must acce...

Reviews: