Features and Specifications
•
CELLARTEC split cooling systems CellarTec 1/8-1/2 Ton-SSL are
designed and used to provide a cold temperature between 50~65
°
F for a
properly insulated wine room at a normal environment.
•
The wine room will maintain humidity of 50~70% RH even when the
environment becomes dry and humid. These temperatures and humilities
are optimized for long term storage of wine.
•
SSL units consist of a condensing unit and an evaporator unit, and they
are connected by a liquid line and an insulated suction line.
•
SSL condensing units can be located away from the evaporator units and
wine cellars as far as 50 feet, which will bring you quiet operation.
•
SSL evaporator units provide low profile and whisper quiet operation. The
evaporator units can be installed on the ceiling in a wine cabinet or room.
The dimensions and capacities are specified as follows:
MODEL
EVAP UNIT
W”xD”xH”
COND UNIT
L”xD”xH”
Btu/h
CFM
(55/90
°
F)
BOTTLE
CAPACITY
(55/75
°
F)
REFRIGERANT
ELECTRICAL
EVAP UNIT/
COND UNIT
WEIGHT(lb)
EVAP UNIT/
COND UNIT
CellarTec
1/8 TON-
SSL
WM-
15SFCL
16.75x14.5
x4.75
WM-150SCU
18x12x14
1500/180
150
cu ft
R134a
115V-60HZ-
0.4A / 115V-
60HZ-3.1A
15/30
CellarTec
1/4 TON-
SSL
WM-
25SFCL
31.75x14.5
x4.75
WM-250SCU
18x12x14
2500/275
250
cu ft
R134a
115V-60HZ-
0.4A / 115V-
60HZ-5.7A
30/40
CellarTec
1/3 TON-
SSL
WM-
45SFCL
40.25x14.5
x4.75
WM-450SCU
18x12x14
4500/460
1000
cu ft
R134a
115V-60HZ-
0.8A / 115V-
60HZ-6.9A
37/60
CellarTec
1/2 TON-
SSL
WM-
65SFCL
53.75x16.5
x6.75
WM-650SCU
24x18x17
6500/575
1500
cu ft
R134a
115V-60HZ-
0.8A / 115V-
60HZ-12A
61/90
Parts included:
Condensing Unit (pressure control, discharge and suction valves installed) +
Sight Glass
Evaporator Unit (liquid line solenoid valve and expansion valve installed)
Temperature Cont Air Sensor
CAUTION:
LIQUID AND SUCTION LINES MAY DIFFER FROM WHAT ARE SHOWN
HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION.
Summary of Contents for 1/2 Ton-SSL
Page 6: ...5 Fig 3 WM150 450SCU Condensing Unit Fig 4 WM 650SCU Condensing Unit...
Page 17: ...16 Fig 15 CellarTec 1 8 1 3 Ton SSL Wiring Diagram...
Page 18: ...17 Fig 16 CellarTec 1 2 Ton SSL Electrical Wiring Diagram...
Page 19: ...18 Fig 17 Low Ambient Temperature CellarTec 1 8 1 3 Ton SSL Electrical Wiring Diagram...
Page 20: ...19 Fig 18 Low Ambient Temperature CellarTec 1 2 Ton SSL Electrical Wiring Diagram...