![Cellartec 1/2 Ton-SSL Installation, Operation & Care Manual Download Page 24](http://html1.mh-extra.com/html/cellartec/1-2-ton-ssl/1-2-ton-ssl_installation-operation-and-care-manual_2580337024.webp)
- 23 -
Fig. 20 System Test
Test Number
Test Type
Description
1 cooling
1-on;
0-off
2 fan
1-on;
0-off
3) Clock Setting
1. Enter the system setup and set 670 = 0 to unlock screen, then exit.
2. Press CLOCK key; press UP/DOWN keys to change clock.
3. Press DONE key to exit.
4. Enter the system setup and set 670 = 2 to lock screen, then exit.
4) Temperature Setting
1. Enter the system setup and set 670 = 0 to unlock screen, then exit.
2. Press UP/DOWN keys to modify temperature.
3. Enter the system setup and set 670 = 2 to lock screen, then exit.
5) Remote Air Sensor
Enter the system setup and set 340 = 3, then exit
6) Humidity Display
It only displays the humidity where the thermostat is installed. The humidity
level is shown in the lower right corner of the screen.