![Cellartec 1/2 Ton-SSL Installation, Operation & Care Manual Download Page 23](http://html1.mh-extra.com/html/cellartec/1-2-ton-ssl/1-2-ton-ssl_installation-operation-and-care-manual_2580337023.webp)
- 22 -
Factory Setup Menu
Setup
Number
Setup Name
Settings
0120
Date (Year Upper)
Select first two digits of current calendar year
0130
Date (Year Lower)
Select last two digits of current calendar year
0140
Date (Month)
Select number for current calendar month
0150
Date (Day)
Select number for current calendar date
0160 Schedule
Options
0-nonprogrammable
0170
System Selection
6-cool only conventional
0220 Cycles
Per
Hour
2
0280
Continuous Backlight
0-not; 1-yes
0300 Changeover
0-manual
0320 Temperature
Display
0-fahrenheit;
1-celsius
0330
Daylight Savings
0-off; 1-on
0340
Remote Air Sensor
0-no; 3-indoor
0380
Indoor Dehumidification
0-no
0580
Min Compressor Off
5-five minutes off
0610
Min Cool Temp
50
°
F
0640
Clock Format
12-12 hour; 24-24 hour
0660
Extended Cool Fan On
0-0 seconds
0670
Keypad Lockout
0-unlocked; 2-fully locked
0690
Cool Temp Control
2-standard
0700 Temperature
Offset
0-no
NOTES:
•
The setup 0660 can be
used to increase the humidity in the wine cellar. The
higher the setting is, the higher the humidity will be.
2) System Test
1. Enter the system setup, and p
ress DOWN key to select setup number.
“TEST” appears at the end of the installer setup number.
2. Press the keys below to test.
Summary of Contents for 1/2 Ton-SSL
Page 6: ...5 Fig 3 WM150 450SCU Condensing Unit Fig 4 WM 650SCU Condensing Unit...
Page 17: ...16 Fig 15 CellarTec 1 8 1 3 Ton SSL Wiring Diagram...
Page 18: ...17 Fig 16 CellarTec 1 2 Ton SSL Electrical Wiring Diagram...
Page 19: ...18 Fig 17 Low Ambient Temperature CellarTec 1 8 1 3 Ton SSL Electrical Wiring Diagram...
Page 20: ...19 Fig 18 Low Ambient Temperature CellarTec 1 2 Ton SSL Electrical Wiring Diagram...