47
V10.19
Remote Control / Display Instructions
Digital Display
The temperature is displayed on the control in red.
Press “Power On/Off” to turn on and off.
When the “Compressor On” indicator light is on, the Compressor is
running.
When the “Fan On” indicator light is on, the Fan is running.
The cooling system is programmed with a Startup Delay to protect its
internal components. Upon installation, we provide instructions for the
installer to change the delay to 30 minutes.
Quick Chill Button
Button
Icon
To activate the “Quick Chill” mode, press the “Up” button for 3 seconds
To deactivate “Quick Chill”, press the “Up” button for three seconds again
The “Quick Chill” indicator (Row 3) light will turn on when the cooling unit
is in “Quick Chill” mode,
In the “Quick Chill” mode, the cooling unit will run continuously for 6 hours
(or until the unit reaches set point.). This mode is useful after loading
“warm” bottles in the cabinet.
Auto Defrost Mode
The cooling unit has a factory default defrost cycle that initiates every 16
hours for 20 minutes. When the cooling unit is in auto-defrost mode, the
“Defrost” Indicator light (Top row) will turn on, and the evaporator fan will
run.
Manual Defrost
Hold the defrost button in for 3 seconds to initiate a manual defrost. The
“Defrost” Indicator light (Top row) will turn on for a 20 minute defrost
cycle.
Light
The light button function is disabled, however pressing it will turn on/off
the light indicator on the display (2nd row).
Energy Saver
The remote display is not configured with an Energy Saver mode. The
set point can be raised manually for periods where energy savings is
desired.
Summary of Contents for 3000Scmr
Page 1: ...V10 19 Control the Elements Split Ceiling Mount Refrigeration Systems Owner sManual...
Page 2: ...V10 19 This page intentionally left blank...
Page 7: ...7 V10 19 Evaporator Cut Sheets...
Page 8: ...8 V10 19 Condensing Unit Cut Sheets...
Page 13: ...13 V10 19 Evaporator Mounting Detail...
Page 20: ...20 V10 19...
Page 22: ...22 V10 19...
Page 23: ...23 V10 19 6000Scm Wiring Diagrams Option A Dual Power Valve Control Page 1 of 2...
Page 24: ...24 V10 19 6000Scm Wiring Diagrams Option A Dual Power Valve Control Page 2 of 2...
Page 25: ...25 V10 19 8000Scm Wiring Diagrams Option A Dual Power Valve Control Page 1 of 2...
Page 26: ...26 V10 19 8000Scm Wiring Diagrams Option A Dual Power Valve Control Page 2 of 2...
Page 28: ...28 V10 19 3000 4000Scm Wiring Diagram Option B Single Power Electronic Control...
Page 30: ...30 V10 19 6000Scm Wiring Diagram Option B Single Power Electronic Control Page 1 of 2...
Page 31: ...31 V10 19 6000Scm Wiring Diagram Option B Single Power Electronic Control Page 2 of 2...
Page 32: ...32 V10 19 8000Scm Wiring Diagram Option B Single Power Electronic Control Page 1 of 2...
Page 33: ...33 V10 19 8000Scm Wiring Diagram Option B Single Power Electronic Control Page 2 of 2...