1.  Carefully remove the microscope and other parts 

from the carton and set them on a table, desk, or 
other fl at surface.

2.  Remove the plastic cover from the microscope.
3.  Plug the small cable from the AC adapter into the 

socket on the back of the base 
(see Figure 2).

4.  Insert the plug you need (see note below) into the 

AC adapter and then plug the adapter into the proper power source.

NOTE:

  The AC Adapter supplied with this microscope has an interchangeable plug system that can work in the 

USA, UK, Europe, Australia, and many other parts of the world.

You can easily change plugs for your particular power requirement: 

A.  You may have one of two different types of adapters. One is shown in 

Figure 3A and another one is somewhat similar shown in Figure 3B. Each 
has a different means of changing plugs.

B.  For the Figure 3A type, push down on the small button labeled “PUSH” 

and hold it down while at the same time holding the prongs of the plug. 
Rotate it slightly counterclockwise and pull up to remove it. Then release 
the “PUSH” button down. 

Take the plug style that you want to use and 

center it over the AC adapter and rotate 
it until it falls into the opening. Rotate it 
clockwise until you hear a click, which lets 
you know the plug is installed correctly.

C.  For the Figure 3B type, pull the plug up and away 

while holding the base of the AC adapter. The plug 
will come off. Take the plug style that you want to 
use and align the two holes in the bottom of the plug 
with the two pins in the AC adapter. Then, push the 
plug into the AC adapter all the way. 

Battery Operation — You can use your microscope 

without AC power if you choose. This gives you the 
freedom to operate the microscope outdoors or indoors 
anywhere you please. You’ll need 4 AA batteries (user 
supplied). Open the battery door on the bottom of the 
microscope and insert the batteries according to the 
battery polarity shown in the battery compartment 
(Figure 4). After the batteries are installed, close the 
battery door. Battery life will typically be three hours.

SETTING UP YOUR MICROSCOPE

MAGNIFICATION (POWER) 

Use the following table to determine the magnifi cation 
of the different objective lenses in combination with 
your microscope using the normal mode of the digital 
image on the LCD screen and using the digital zoom 
feature.

SPECIFICATIONS

Stage 

Mechanical Stage 3.5 in x 3.5 in (88 mm x 88 mm)

Digital Camera 

5 MP 1/2.5” CMOS; 10x Magnifi cation in lieu of an eyepiece 

LCD Monitor

4.3 in. (109 mm)  TFT LCD touch screen with 4x digital zoom —

                                     Touch digital TFT display    
 

Resolution — 480 x 272 pixels

Focuser  

Dual — Coarse/Fine

Objectives 

 Achromatic, glass type — 4x, 10x 20x, 40x and 60x  

Memory 

8 GB SD card (approximately 2200+ snapshots @ 5 MP) 

LCD Rotation 

180° – 90° left / 90° right

Filter Wheel 

Red/Green/Blue/1 mm hole/3 mm hole/6 mm hole (default)

Nosepiece  

Quad with click stop

Illuminator 

Built-in electric — LED 6 Volt and 6 Watt

Condenser  

N.A. 0.65

AC Adapter  

Input Universal 100 to 240 Volt 50/60HZ

Batteries 

User supplied 4 AA — (optional - up to 3 hours usage)

Weight/Dimensions   67 oz/1.9 kg 7.0” (178 mm) x 5.5 in (140 mm) x 13.0 in (330 mm)

Fig 3A

Fig 4

Fig 3B

TOUCH PEN

You can keep the touch pen handy in 
the receptable behind the Power ON/OFF button.

MAGNIFICATION (POWER) 

Use the following table to determine the magnifi cation 
of the different objective lenses in combination with 
your microscope using the normal mode of the digital 
image on the LCD screen and using the digital zoom 
feature.

© 2019 Celestron • All rights reserved • celestron.com/pages/technical-support • 2835 Columbia Street • Torrance, CA 90503 USA • 12-19
celestron.com/support/warranties

Product design and specifi cations are subject to change without prior notifi cation. This product is designed and intended for use by those 14 years of age and older.

Objective Lens             4x     10x     20x       40x      60x     
Digital Image               40x    100x    200x   400x    600x    
Maximum with 4x 
digital zoom feature    160x   400x    800x   1600x   2400x

WORKING DISTANCE

Objective Lens             4x      10x      20x     40x     60x

Working 
Distance (mm) - est.      35.3   7.8      1.9     0.7      0.2   

Touch Pen

ON/OFF Button

Fig 2

Summary of Contents for PentaView 44348

Page 1: ...QUICK START GUIDE GUIDE DE D MARRAGE RAPIDE KURZANLEITUNG GUIDA AVVIO RAPIDO GU A DE INICIO R PIDO 44348 LCD DIGITAL MICROSCOPE TM...

Page 2: ...a 5MP camera sensor in lieu of an eyepiece You will view specimens on the LCD screen In addition the sensor allows you to take snapshots or short videos Plus you can view on most TV screens with the...

Page 3: ...t Figure 4 After the batteries are installed close the battery door Battery life will typically be three hours SETTING UP YOUR MICROSCOPE MAGNIFICATION POWER Use the following table to determine the m...

Page 4: ...cimens ou des objets sur l cran LCD qui sont faciles observer et vous pouvez aussi en profi ter avec les autres En outre vous pouvez prendre des photos ou des vid os de courte dur e avec l appareil ph...

Page 5: ...timent de piles Figure 4 Apr s l installation des piles fermer la porte du compartiment La dur e des piles est typiquement de trois heures INSTALLATION DE VOTRE MICROSCOPE TABLE DE GROSSISSEMENT Consu...

Page 6: ...ie bei herk mmlichen Mikroskopen verwendet werden Proben oder Objekte werden Sie auf dem LCD Bildschirm angezeigt was die Betrachtung einfach macht und die M glichkeit bietet sich gemeinsam mit andere...

Page 7: ...fu und legen Sie die Batterien entsprechend der im Batteriefach angezeigten Polarit t Abbildung 4 ein Nachdem die Batterien eingelegt wurden schlie en Sie das Batteriefach Die Batterielebensdauer betr...

Page 8: ...chermo LCD di facile visualizzazione e sar inoltre possibile condividere le immagini con altri Inoltre possibile scattare istantanee o brevi video con la fotocamera digitale integrata E ancora sar pos...

Page 9: ...in base alla polarit indicata nel compartimento delle batterie Figura 4 Una volta installate le batterie chiudere il vano La durata della batteria normalmente di tre ore CONFIGURAZIONE DEL MICROSCOPIO...

Page 10: ...etos en la pantalla LCD f cil de observar y podr disfrutar con otras personas Adem s puede tomar capturas o breves videos con la c mara digital integrada Tambi n podr observar en la mayor a de pantall...

Page 11: ...do haya instalado las bater as cierre la tapa La duraci n de las bater as ser normalmente de tres horas CONFIGURACI N DE SU MICROSCOPIO TABLA DE AUMENTO POTENCIA Use la tabla siguiente para determinar...

Page 12: ......

Reviews: