background image

25

a

ppendIX

 C - rs-232 C

onneCTIon

 

Description

PC Command ASCII

Hand Control Response

Notes

Echo

Kx

x#

Useful to check 

communication

Goto Azm-Alt

B12AB, 4000

#

10 characters sent . 

B=Command, 12AB=Azm, 

comma, 4000=Alt . If 

command conflicts with 

slew limits, there will be  

no action .

Goto Ra-Dec

R34AB, 12CE

#

Scope must be aligned . 

If command conflicts with 

slew limits, there will be  

no action .

Get Azm-Alt

Z

12AB, 4000#

10 characters returned, 

12AB=Azm, comma, 

4000=Alt, #

Get RA-Dec

E

34AB, 12CE#

Scope must be aligned

Cancel Goto

M

#

Is Goto in Progress

L

0# or 1#

0=No, 1=Yes; "0" is ASCII 

character zero

Is Alignment Complete

J

0# or 1#

0=No, 1=Yes

Commands below 
available on version  
1.6 or later

HC version

V

22

Two bytes representing V2 .2

Stop/Start Tracking

Tx 

x = 0 (Tracking off) 

x = 1 (Alt-Az on) 

x = 2 (EQ-N) 

x = 3 (EQ-S)

#

Alt-Az tracking requires 

alignment

32-bit goto RA-Dec

r34AB0500,12CE0500

#

32-bit get RA-Dec

e

34AB0500,12CE0500#

The last two characters will 

always be zero .

Commands below 
available on version  
2.2 or later

32-bit goto Azm-Alt

b34AB0500,12CE0500

#

32-bit get Azm-Alt

z

34AB0500,12CE0500#

The last two characters will 

always be zero .

t

he

 

Cable

 

requireD

 

to

 

interFaCe

 

to

  

the

 

telesCoPe

 

has

 

an

 rs-232 

Male

 

Plug

 

at

 

one

 

enD

 

anD

 

a

  

4-4 

telePhone

 

jaCk

 

at

 

the

 

other

 

enD

. t

he

 

wiring

 

is

 

as

 

Follows

:

4-4 Modular 

Phone Jack

DB9 Pin 3 

PC Transmit

DB9 Pin 2 

PC Recieve

DB9 Pin 5 

Ground

Summary of Contents for CGEM DX

Page 1: ...INSTRUCTION MANUAL CGEM DX Computerized Mount ENGLISH...

Page 2: ...n Tour 11 Direction Buttons 11 Rate Button 11 Setup Procedures 11 Tracking Mode 11 Tracking Rate 11 Date Time 11 User Defined Objects 11 Get RA DEC 12 Goto R A Dec 12 Identify 12 Precise GoTo 12 Scope...

Page 3: ...to become familiar with your mount so you should keep this manual handy until you have fully mastered your telescope s operation The hand control has built in instructions to guide you through all the...

Page 4: ...stment Knob 3 Tripod 4 Hand Control 5 Tripod Center Leg Brace Accessory Tray 6 Counterweight s 7 Counterweight Bar 8 Telescope Mounting Platform Control Panel A On Off Switch B 12v Input Jack C Hand C...

Page 5: ...y tray far enough to rotate it until the three recesses line up with each leg Collapse the legs so that each leg falls into one of the recesses Secure the legs together with the nylon strap attached t...

Page 6: ...hten the counterweight bar lock nut fully for added support Once the bar is securely in place you are ready to attach the counterweight Since the fully assembled telescope can be quite heavy position...

Page 7: ...R A and DEC clutch knobs slightly and move the telescope in the desired direction Both the R A and DEC axis have lock levers to clutch down each axis of the telescope To loosen the clutches on the te...

Page 8: ...r latitude adjustment knob and tighten the front screw if necessary The latitude adjustment on the mount has a range from approximately 15 to 70 It is best to always make final adjustments in latitude...

Page 9: ...e database 6 Tour Activates the tour mode which seeks out all the best objects for the current date and time and automatically slews the telescope to those objects 7 Enter Pressing Enter allows you to...

Page 10: ...nternational or U S location Custom Site allows you to enter the exact longitude and latitude of your observing site Select City Database and press ENTER The hand control will allow you to choose from...

Page 11: ...em Align Solar System Align is designed to provide excellent tracking and GoTo performance by using solar system objects Sun Moon and planets to align the telescope with the sky Solar System Align is...

Page 12: ...control to select Alignment Stars from the list of options 5 The display will then ask you which alignment star you want to replace Use the UP and Down scroll keys to select the alignment star to be...

Page 13: ...ase the slew rate to the maximum slew rate The direction that a star moves in the eyepiece when a direction is pressed will change depending on which side of the Meridian the telescope tube is positio...

Page 14: ...bjects you are currently observing For example if your telescope is pointed at the brightest star in the constellation Lyra choosing Identify and then searching the Named Star catalog will no doubt re...

Page 15: ...reverse the button logic of the hand control press the MENU button and select Direction Buttons from the Utilities menu Use the Up Down arrow keys 10 to select either the azimuth right ascension or al...

Page 16: ...s section below the values are stored and displayed in the hand control It is not recommended that the calibration values be changed however each setting can be changed if necessary to improve the per...

Page 17: ...lescope Goto Axis Position Allows you to enter a specific altitude and azimuth position and slew to it Hibernate Hibernate allows the telescope to be completely powered down and still retain its align...

Page 18: ...errors and improving the tracking accuracy of the drive This feature is for advanced astrophotography and is used when your telescope is accurately polar aligned For more information on using PEC see...

Page 19: ...NT POSITION TURN ON OFF GPS PEC USER OBJECTS IDENTIFY GOTO RA DEC GET RA DEC PRECISE GOTO GOTO SKY OBJECT SAVE SKY OBJECT SAVE DB OBJECT ENTER RA DEC GOTO LAND OBJECT SAVE LAND OBJECT TURN ON OFF RTC...

Page 20: ...h s rotation The Earth s rotation also causes the stars to do the same scribing out a large circle as the Earth completes one rotation The size of the circular path a star follows depends on where it...

Page 21: ...Up Down buttons on the hand controller to select Polar Align from the list The Polar Align feature has two options Align Mount After performing a two star alignment and slewing your telescope to any b...

Page 22: ...s pointed at the celestial pole it is parallel to the Earth s rotational axis Many methods of polar alignment require that you know how to find the celestial pole by identifying stars in the area For...

Page 23: ...nderscope has an easy to use laser etched reticle PowerTank 18774 12v 7Amp hour rechargeable power supply Comes with two 12v output cigarette outlets built in red flash light Halogen emergency spotlig...

Page 24: ...magingObjects 25 SelectedSAOStars 29 500 Userdefined SkyObjects 99 Userdefined LandObjects 9 TotalObjectDatabase 45 492 Appendix A Technical Specifications Appendix B Glossary Of Terms A Absolute The...

Page 25: ...ial An imaginary sphere surrounding the Earth Sphere concentric with the Earth s center Collimation The act of putting a telescope s optics into perfect alignment D Declination The angular distance of...

Page 26: ...resolved into an image because it to too far away or too small is considered a point source A planet is far away but it can be resolved as a disk Most stars cannot be resolved as disks they are too f...

Page 27: ...o Is Alignment Complete J 0 or 1 0 No 1 Yes Commands below available on version 1 6 or later HC version V 22 Two bytes representing V2 2 Stop Start Tracking Tx x 0 Tracking off x 1 Alt Az on x 2 EQ N...

Page 28: ...note Only valid for motorcontrol version 4 1 or greater 1 Convert the angle position to a 24bit number Example if the desired position is 220 then POSITION_24BIT 220 360 x 224 10 252 743 2 Separate P...

Page 29: ...27 Appendix D Maps Of Time Zones...

Page 30: ...28...

Page 31: ...29 Sky Maps...

Page 32: ...30...

Page 33: ...31...

Page 34: ...32...

Page 35: ...33...

Page 36: ...34...

Page 37: ...ng or unauthorized repair Further product malfunction or deterioration due to normal wear is not covered by this warranty CELESTRON DISCLAIMS ANY WARRANTIES EXPRESS OR IMPLIED WHETHER OF MERCHANTABILI...

Page 38: ...CA 90503 U S A Telephone 310 328 9560 Fax 310 212 5835 2011 Celestron All rights reserved Printed in China 01 11 Product design and specifications are 91528 INST 10 00 subject to change without prior...

Reviews: