5.2.3. 1-WIRE CONFIGURATION

Section

 1-WIRE bus 

has options

:

Baud rate

: standard (at the moment available is standard baud rate),

Number of groups in searching process

:

 readout only,

List of available group of 1-WIRE sensor/systems in searching process

 (readout only).

5.2.4. MEASUREMENT CONFIGURATION

Section 

Measurement configuration

 has options: 

Measuring data format: 

integral number with 2-byte (readout only),

Pause between readout:

 interval between another readout of measurement from connected sensors - range 1 – 255 sec.

Enable single reading sensors:

 enable this option causes that each sensor is readout separately. The time of readout one sensor

is about 1 sec.

The effect of this option is:

- extension measurement readout time from sensors,

- reducing current value, being in VDD line or DQ, to current value one sensor in time of measurement processing. It is imported in

potentially explosive environments, after connection an intrinsically safe barrier to ADA-401WP.

Enable write TL and TH registers for DS18xxx:

 enable this option causes that change of Lo and Hi values in the configuration on

measurement channel is write in TL and TH registers of DS18xxx sensor and readout from these registers. Disable this option

causes that Lo and Hi values setted in the measurement channel configuration are written to ADA-401WP memory and readout

from there. 

Options  

 

 Enable single reading sensors  

 

 

and

     Enable write TL and TH registers for DS18xxx  

 

 

are available from 2,005 firmware

version and 1.7.1.0 version of ADAUtil.

5.2.5. AUTOMATIC ASSIGN SENSORS TO MEASUREMENT CHANNELS (AAS) CONFIGURATION

AAS function lets quickly assign sensors to measuring channels in the order specified by their heating temperature AAS. Description
of using the AAS function is described in point 

CHANGING SENSORS ORDER BY THE USE OF AAS PROCEDURE

Configuration of 

AAS function :

 

Enable Automatic Assign Temperature Sensor to Measure Channel

: enable or disable module AAS function,

Temperature AAS

0 – 50 °C, - setting of AAS temperature above followed by automatic assignment of the sensor to a channel.

After configuration press button 

Save configuration to module

Set SW1 switch section to run mode as in the table below.

SW1-1

SW1-2

OFF

OFF

Yellow LED will be OFF.

5.3. MEASURING CHANNEL CONFIGURATION

Set the SW1 micro switch in the configuration mode as table below

SW1-1

SW1-2

ON

OFF

Yellow LED will blink with frequency 1 Hz.

5.3.1. SENSOR ADDING 

After   connecting   sensors   to   ADA-401WP,   according   to   point  

CONNECTION   TEMPERATURE   SENSORS

  and   running  

ADAUtil

software

, select branch 

Configuration=>Communication 

on left panel, and on right select COM port used for module configuration.

Then   on   left   panel   select   branch  

Configuration

=>

Communication

=>ADA-401WP=>Measure   channels

  and   on   right   will   open

[Measure channels configuration and diagnostic]

  and press [

Read Configuration form Module] –  

readout the configuration of

measurement channels from ADA-401WP. 

11

ADA-401WP

Summary of Contents for ADA-401WP

Page 1: ...User manual ADA 401WP 1 WIRE to MODBUS RTU Measuring Module 1 io_ada 401wp_v 1 24_en ADA 401WP Copyright 2001 2017 CEL MAR sp j...

Page 2: ...1 SENSOR DISPLACEMENT 13 5 3 2 2 SENSORS EXCHANGE 13 5 3 2 3 CHANGING TEMPERATURE SENSORS ORDER BY THE USE OF AAS PROCEDURE 13 5 3 3 SENSORS REMOVING 14 5 3 4 MEASUREMENT CHANNEL PARAMETERS CONFIGURAT...

Page 3: ...MEASURING CHANNEL 4X 3X REFERENCES 24 7 3 1 8 FUNCTION 0x03 0x04 READOUT OF CO2 CONCENTRATION MEASURING CHANNEL 4X 3X REFERENCES 24 7 3 1 9 FUNCTION 0x03 0x04 READOUT OF TEMPERATURE VALUE OF SENSOR PT...

Page 4: ...ly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical 1 3 CE LABEL The CE...

Page 5: ...485 line is made on the basis of 600W protectors diodes and fuses To RS485 Bus can be connected 32 devices ADA 401WP Additional converter like ADA I1040 RS232 to RS485 or ADA I9140 USB to RS485 enabl...

Page 6: ...erter from power circuit device that generates large impulse interference such as transmitters contactors 3 1 ASSEMBLING ADA 401WP enclosure is adapted to assembly on TS 35 DIN35 rail To install shoul...

Page 7: ...Bd Should be used Line Termination resistor if the distance is over 1000m 9600Bd or 700m 19200Bd transmission Example connection of Rt connected to screw terminal block of RS485 422 interface are show...

Page 8: ...500 However when building the network remember that each sensor is a shortening of 0 5 meters and 100 meters of cable causes additional capacity load data line 5nF increasing signal distortion The rea...

Page 9: ...ecking RS485 interface Diagnosis 1 WIRE interface Diagnostic System Diagnostic Measurement channels Diagnostic 5 CONFIGURATION Configuration of ADA 401WP module should be made by the use of ADAUtil so...

Page 10: ...disable disable manufacturer setting Errors that are signalled by short sound errors of sensors searching errors of reading temperature from sensors errors in RS485 communication errors of CRC sensor...

Page 11: ...ingle reading sensors and Enable write TL and TH registers for DS18xxx are available from 2 005 firmware version and 1 7 1 0 version of ADAUtil 5 2 5 AUTOMATIC ASSIGN SENSORS TO MEASUREMENT CHANNELS A...

Page 12: ...the table below Table indications of sensors Sensor Unit of measurement Sensor Unit of measurement Temperature C voltage converter 0 10V DC V U10 Relative humidity RH current converter 0 2mA DC mA A2...

Page 13: ...iguration to module memory by pressing button Save Configuration to Module To the module memory will be saved only configuration of measuring channels which fields were marked in ping 5 3 2 3 CHANGING...

Page 14: ...hPa to 12 70hPa for digital atmospheric pressure sensors DES 216 AP DES 300 AP etc Enable activation this field will cues actualisation of measurement and status for channel deactivation will cues blo...

Page 15: ...in loaded file can be changed the module software Process of software update is visualized by ADAUtil in use of Progress Window and after proper update confirmed by correct message Fig 11 Choice of s...

Page 16: ...mode value visualization of temperature measurement with the 0 5 C accuracy transmission errors on the 1 WIRE bus restore factory default and reset register Set the SW1 microswitch as in the table bel...

Page 17: ...ter counter of Button the number of RST Reset button Register counter of Brown On specifies the number of the operating voltage drops below allowable voltage level After that can be set the switch sec...

Page 18: ...ble below SW1 1 SW1 2 OFF OFF Yellow LED will be OFF 6 3 DIAGNOSTIC OF MODBUS PROTOCOL After finishing diagnostic of measurement channels of each ADA 401WP module in installation can be started diagno...

Page 19: ...ters of channels 6 3 1 CONFIGURATION OF MODBUS RTU COMMUNICATION MODBUS Monitoring window has options for configuration of MODBUS RTU communication Module Address 1 247 enter the address of ADA 401WP...

Page 20: ...sation of measurement and status for channel deactivation will cues block actualisation Assigned activation this field will cues adding a sensor to the Channel Deactivation will cues that in case of n...

Page 21: ...condition R 16 bit register 30202 40202 1 201 Channel condition R 16 bit register 30203 40203 2 202 Channel condition R 16 bit register 30204 40204 3 203 Channel condition R 16 bit register 30204 4020...

Page 22: ...re C 100 PT1000 sensor s temperature C PT1000 10 Relative humidity RH 10 0 10VDC transducer V U10 100 Lighting natural or unnatural Lux 10 0 20mADC transducer mA A20 100 Sunlight SLux 10 Circuit DS240...

Page 23: ...during inquiry converting 03 CRC Lo 1 byte 04 CRC Hi 1 byte 7 3 1 2 FUNCTION 0x03 0x04 READOUT OF RELATIVE HUMIDITY FROM MEASURING CHANNEL 4X 3X REFERENCES Function 0x03 0x04 are used for readout of...

Page 24: ...CTION 0x03 0x04 READOUT OF CO2 CONCENTRATION MEASURING CHANNEL 4X 3X REFERENCES Function 0x03 0x04 are used for readout of the value from measuring channel sensor The value from measuring channel sens...

Page 25: ...erial number 40 0 402 Byte 4 of serial number 01 Bajt 5 of serial number 00 0 403 Byte 6 of serial number 00 Bajt 7 of serial number 23 Query of circuit serial number from channel nr 0 Byte no Designa...

Page 26: ...status Byte Hi from ver 1 008 firmware 0 Sensor in processing 0 No 1 Yes 0 Short circuit on the 1 Wire bus 0 No 1 Yes 1 Sensor detected 0 No 1 Yes 1 DS18xx circuit present on 1 WIRE bus 0 0 No 1 Yes 2...

Page 27: ...1 byte 83 84 02 Error code 1 byte 01 unknown function 02 unknown data address 03 unknown data value 04 unknown error while inquiry converting 03 CRC Lo 1 byte 04 CRC Hi 1 byte 8 SPECIFICATION TECHNICA...

Page 28: ...ng Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standard DIN EN50022 DIN EN43880 Location during work Free Mounting method On the rail compliant with...

Reviews: