12 Maintenance
FI100K0025v1100 UK - - PD240CH
3 Maintenance
3.1 Periodic
maintenance
3.1.1 Cleaning
Use a slightly moist, nonabrasive cloth for cleaning.
Do not wash the device with liquid detergents or chemical substances.
3.1.2 Battery
Keep the battery charger pins present on the metal detector handle and on the
HHDS
module clean, to ensure proper electric contact.
In
case
of a prolonged period of storage/unuse Ni-MH batteries lose naturally
almost all their charge and then they might have difficulties in recharging. In
order to prevent that, we recommend that they undergo a complete charge
cycle at least every 4 months even when unused. Recharge the batteries every
month to keep them always ready to use (charge at 80% or more).
3.2 Troubleshooting
Signal or symptom
Probable cause
Action
Alarm signal after start-
up.
Start-up carried out
near a metal mass.
Move the deìector away from the
metal mass and reset the detector
(refer to section “Alarm Reset”.
Electromagnetic
sources present near
the detector:
- Other
hand-held
metal detectors
with the same
operating channel
Use hand-held metal detector with
different operating channel (using
the accessory
HHMD Configuration
Tool
).
- Walk-through
metal
detectors or other
electromagnetic
sources in close
proximity
Increase distance.
Use hand-held metal detector with
different operating channel (using
the accessory
HHMD Configuration
Tool
).