Maintenance
13
FI100K0025v1100 UK - - PD240CH
Signal or symptom
Probable cause
Action
Both intermittent RED
alarm and audio signals
during use.
Fault
Discontinue equipment use and
contact service department.
Operational verification
failure.
Test procedure carried
out incorrectly.
Power cycle the detector, wait for
“ready for use” signal and repeat the
procedure correctly.
In case of repeated failure,
discontinue equipment use and
contact service department.
Battery charging process
does not start.
Wrong procedure or
dirty electric contacts.
Extract the detector from
HHDS
module and verify that it is off. Verify
that the
HHDS
is connected to the
AC power supply. Place again the
detector inside the
HHDS
module.
In case of repeated failure:
-
Verify that the AC power supply
is available
-
Check that the contacts of the
detector and the spring pins of
the
HHDS
are clean and
working properly
- replace
HHDS
module
In case of repeated failure,
discontinue equipment use and
contact service department.
Intermittent RED alarm
during battery charging
process
Dirty electric contacts
Check that the contacts of the
detector and the spring pins of the
HHDS
are clean and working
properly.
Damaged battery,
absent or wrongly
inserted.
Check the batteries condition and
replace them if necessary (see
procedure below).
3.3
Procedure for replacing batteries
Remove the locking screw from the cap of the battery compartment, using a TORX 10
key. Replace the batteries, respecting their polarity, as illustrated in the figure below.
Replace the battery compartment cap and secure it tightening the locking screw.