10 Use
FI100K0025v1100 UK - - PD240CH
2.8
Automatic stand-by
Metal free table
Standard Stand-by mode
The device enters stand-by mode, reducing power consumption,
in case of no operation for 3 minutes (time adjustable on
customer request).
Stand-by after 180s
This function is enabled by default, but can be disabled on customer request
or using HHMD Configuration Tool. .
Table with metal parts
Quick Stand-by mode
In case the detector rests facing up, as illustrated in the figure on
the left, on a horizontal surface containing metal parts, the unit
quickly enters stand-by mode, after a short alarm.
Alarm
immediate Stand-by
This function is disabled by default, but can be enabled on customer request
or using HHMD Configuration Tool.
Restart
To restart the unit, simply move it: the detector will be
immediately ready for use.
2.9
Automatic turning off
The device switches off completely after a stand-by state exceeding 40 minutes (time
adjustable on customer request).
This function can be disabled, on customer request or using HHMD Configuration Tool.
2.10
Turning off
Keep pressed
push button for at least 3 seconds. RED lights will turn on in sequence
and then the device turns off (all indicators off).
>3s