- Ensure correct suction pipe sizes - see Tables 3.0, 3.1 and Chart 1.0
- Ensure inlet and outlet pipes are correctly installed and tightened
- Release the top priming plug (found on the stainless steel pump body) by turning anti-clockwise 3/4 of a turn with a
14mm ring spanner. This will release air pressure allowing the pump to fill sufficiently (ensure that the water supply
has been turned on). Once air has released and water begins to spill, then fasten the priming plug
- Open main discharge valve
- Plug pump into main socket
- Run the highest and furthest valve/tap from the pump for 2 minutes (e.g. shower or garden tap on opposite side of
house)
- Close the discharge valve once excess air has evacuated the system
- Check for any leaks around the inlet/outlet pipes and the pump while the pump is still running
- Unplug the pump from main socket
- Check for any leaks around the inlet/outlet pipes and the pump when the pump is turned off
- If leaks are present, please tend to appropriately
- If no leaks are present, plug in pump to begin use of your ECO-MXA
Leaks of any size, large or small will cause the pump to cycle and not function correctly and may void the warranty!
INSTALLATION FOR FLOODED SUCTION
- Check to ensure that a sufficient water level is available in the supply tank
- Ensure that the ECO-MXA is securely fastened to stop any vibration that may cause slow wear of the pump
- Ensure that the pump is unplugged
Non-return valve
- Electrical plug connections must be made in flood-safe locations and be protected from moisture
- Check available power supply
- Verify that the voltage and frequency of the ECO-MXA pump shown on the nameplate corresponds to those available
on the supply
- Observe local earthing requirements (do not cut off earth pin or use an adapter fitting)
- Pumps must only be operated with electrical cables or extension leads up to a maximum of 10 metres
Do not use the pump if the power cord or plug are damaged. If damaged, please get these replaced by
qualified personnel!!
All electrical work to be carried out by a qualified and locally licensed electrician in strict conformity with
local regulations!
Drawing 3.0
- Ensure suction pipe has non-return valve (provided) fitted to the discharge of the water supply,
or fitted to the bottom end of the suction pipe.
- Ensure the non-return valve is installed in the correct direction