5.0  RECOMMENDED TOOLS AND TEST EQUIPMENT 

 
      

DTMF Test Set 

      

Volt/Ohm Meter 

      

3/8" Nut Driver 

      

5/16" Nut Driver 

      

Flat Blade Screw Driver 

     

Security Tool CEECO P/N 301-064

 

 

6.0  INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 

       

6.1

    Using a 301-064 security tool (

sold separately

) remove the four security 

screws. 

 

6.2

    The security tool is for a standard 5/32" button head screw generally used 

on the framework of the phone booths. 

 
 

6.3

    Separate the cover assembly from the housing. 

 

6.4

    Run the inside station wire through the housing and terminate on to the 

RJ11C modular jack, as depicted on the following page.  The CEECO-
provided modular jack must be used, as it contains required over-voltage 
protection. 

      

6.5

    The use of a gas tube or carbon station protector is recommended.  The 

station ground should not exceed 50 ohms. 

 

6.6

    Plug the modular line cord from the SPK 660-000 PC board into the 

RJ11C terminal block. 

 

6.7

    Dress the line cord away from the security screws and seat the faceplate 

into the enclosure. 

 
 

6.8

  

Secure the cover assembly by tightening the security screws. 

 

        

*****WARNING***** 

 
        

A.  

Never install telephone wiring during a lightning storm. 

 

B.  

Never install telephone jacks in wet locations unless the jack is 
specifically designed for wet locations. 

          

   

 

 

 

C. 

Never touches uninsulated telephone wires or terminals unless the 
telephone line has been disconnected at the network interface. 

          

 

         D.  

Use caution when installing or modifying telephone lines. 

Summary of Contents for SSP-571-D2

Page 1: ...DS FREE PANEL TELEPHONE EQUIPPED WITH SPK1 07UNVL FIRMWARE WITH OPTIONAL SECOND NUMBER AUTO DIAL FEATURE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engin...

Page 2: ...for assistance MODEL NUMBER MODEL SSP 571 D2 EQUIPPED WITH SPK1 07UNVL FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available wh...

Page 3: ...TION 4 2 0 GENERAL 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 8 4 0 TESTING OPERATION 8 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 9 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 9 7 0 SPECIFICATIONS...

Page 4: ...istant Stainless Steel Panel Speakerphone Instead of a hookswitch and handset the SSP 571 D2 has a Press to start Press to stop CALL button for the initiation and termination of phone calls 2 2 The mi...

Page 5: ...last page of this manual 3 4 Press the CALL button and wait for dial tone before programming any digits 3 5 It is important to be slow and deliberate when pressing the keys of the programming keypad A...

Page 6: ...0 No second number auto dial feature 1 9 Activate second number auto dial feature to occur after this number of rings Digit 7 0 Always 0 for this model Digit 8 PBX Access see section 3 9 0 Do not dial...

Page 7: ...___ ___ ___ ___ Example Enter 1 9 5 5 5 1 2 1 2 This will program the phone to automatically dial the number 555 1212 whenever the CALL button is pressed 3 9 If it is necessary for the telephone to a...

Page 8: ...he CALL button located on the front of the phone When dial tone is received the transmitter is muted and the phone waits for numbers to be dialed The LED will light RED at this time and the preprogram...

Page 9: ...e following page The CEECO provided modular jack must be used as it contains required over voltage protection 6 5 The use of a gas tube or carbon station protector is recommended The station ground sh...

Page 10: ...NE POWERED LOOP CURRENT 30a MIN 80ma MAX IMPEDANCE 600 Ohms SIGNALING DTMF 70ms tone 50ms spacing OUTPUT 4 0 to 6 0dbm ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating PROGRAMMING...

Page 11: ...OVER SECURITY SCREW 1 301 018 MODULAR LINE CORD 1 379 300 FACE PLATE 1 301 054 MODULAR CONNECTOR RJ11C 1 379 200 SERVICE MANUAL 1 700 008 KEYPAD CABLE 1 660 000 CEECO SPK BOARD 1 705 110 CONNECTORIZED...

Page 12: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHO...

Page 13: ...ENT 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay th...

Page 14: ...t found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse or improper op...

Page 15: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BE...

Reviews: