CEECO SSP-373-D Service Manual Download Page 9

ISSUE 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

9

7.0 SPECIFICATIONS 

 

INPUT POWER: 

 

 

C.O. Line Powered 

 
LOOP CURRENT:   

 

23 mA min. to 80 mA max.  

 
IMPEDANCE:   600 

ohms 

 
SIGNALING:  

 

 

DTMF, 70ms tone, 50ms spacing 

 

 

 

 

 

 

 

 

 

 

HEARING 

AID    

 

COMPATIBILITY: 

  Meets 

EIA 

standards 

 
ENVIRONMENTAL: 

  Temperature 

0ºC 

to 

50ºC 

     Humidity 

20%-90% 

non-condensating 

 

 

 
TELEPHONE PANEL: 

 

Brushed 16-gauge stainless steel 

 
DIMENSIONS:   6 

7/8

W x 9 3/4

H x 3

D  

(handset on hook) 

 
MOUNTING:  

 

 

Vertical surface or enclosure mount 

 
WEIGHT: 

   Approximately 

lb. 

 
RINGER EQUIVALENCY:   

0.8A 

 
FCC REGISTRATION NO.:  

BW-88T7-13717-TE-T 

 
UL LISTED NO.: 

 

 

60F5 

 
TYPE 

JACK: 

   RJ11C 

 

Summary of Contents for SSP-373-D

Page 1: ...SSP 373 D STAINLESS STEEL ELEVATOR AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2 01 FIMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Comp...

Page 2: ...for assistance MODEL NUMBER MODEL SSP 373 D EQUIPPED WITH ADI2 01 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when ca...

Page 3: ...4 2 0 GENERAL DESCRIPTION 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 4 0 TESTING OPERATION 7 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 SPECIFIC...

Page 4: ...Model SSP 373 D Automatic Dialing Telephone is a microprocessor based typical elevator style telephone housed in a rugged stainless steel case 2 2 The telephone is designed to provide typical elevato...

Page 5: ...is essential to press the keys deliberately and slowly Missed or partial tones will result in improper programming 3 5 If the phone must automatically dial a number when the handset is lifted enter 1...

Page 6: ...on the programming keypad 3 7 Enter 0 0 on the keypad This accesses the telephone options programming location Now enter three digits which you will select from the options below to customize the pho...

Page 7: ...d dial that second number Remember that Digit 1 under Location 00 must be set to 1 for Location 20 to be enabled If the second number does not dial out repeat sections 3 3 3 5 3 6 3 7 and 3 8 If this...

Page 8: ...nd terminate to an RJ11C modular jack or terminal block 6 3 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 4 Plug the modular line cord from the...

Page 9: ...ne 50ms spacing HEARING AID COMPATIBILITY Meets EIA standards ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating TELEPHONE PANEL Brushed 16 gauge stainless steel DIMENSIONS 6 7 8 W...

Page 10: ...panel 1 371 014 Handset with coiled cord magnetic plate 1 928 001 Strain relief bushing 2 945 001 Magnetic reed switch assembly 1 341 018 Modular cord 2 371 009A Mounting support bracket 1 650 541 MC...

Page 11: ...Telephone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE T...

Page 12: ...rtment 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay...

Page 13: ...r replace any unit during this period if found to be defective for reasons other than abuse and improper use or improper installation It is the buyer s responsibility to return the defective unit to t...

Page 14: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BE...

Reviews: