9.0 FCC 

NOTICE 

 
 

9.1 

FCC REGISTRATION AND REPAIR INFORMATION  

 

Your new telephone has been registered with the Federal Communication 
Commission (FCC) in accordance with Part 68 of its rules. The FCC 
requires that you be advised of certain requirements involving the use of 
this telephone. 

 

9.2

 

CONNECTION AND USE WITH THE NATIONWIDE TELEPHONE 
NETWORK.  

 

The FCC requires that you connect this telephone to the Nationwide 
Telephone Network through a registered jack provided by the Telephone 
Company in your area.  This jack is a modular outlet, which you can order 
from your local telephone company. 

 
 

9.3

 

NOTIFICATION TO THE TELEPHONE COMPANY  

 

Before connecting this telephone, the FCC requires that you notify your 
local telephone company business office.  The number is in the front of 
your phone book. 

 
  Tell 

them: 

 

The "line" to which you will connect the telephone (that is, your phone 
number), the telephone's FCC registration number and ringer equivalence 
number.  These numbers are listed in section 7.0 

 

The FCC further requires that you notify your local telephone company 
when permanently disconnecting this telephone. 

Summary of Contents for SSP-373-D

Page 1: ...SSP 373 D STAINLESS STEEL ELEVATOR AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2 01 FIMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Comp...

Page 2: ...for assistance MODEL NUMBER MODEL SSP 373 D EQUIPPED WITH ADI2 01 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when ca...

Page 3: ...4 2 0 GENERAL DESCRIPTION 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 4 0 TESTING OPERATION 7 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 SPECIFIC...

Page 4: ...Model SSP 373 D Automatic Dialing Telephone is a microprocessor based typical elevator style telephone housed in a rugged stainless steel case 2 2 The telephone is designed to provide typical elevato...

Page 5: ...is essential to press the keys deliberately and slowly Missed or partial tones will result in improper programming 3 5 If the phone must automatically dial a number when the handset is lifted enter 1...

Page 6: ...on the programming keypad 3 7 Enter 0 0 on the keypad This accesses the telephone options programming location Now enter three digits which you will select from the options below to customize the pho...

Page 7: ...d dial that second number Remember that Digit 1 under Location 00 must be set to 1 for Location 20 to be enabled If the second number does not dial out repeat sections 3 3 3 5 3 6 3 7 and 3 8 If this...

Page 8: ...nd terminate to an RJ11C modular jack or terminal block 6 3 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 4 Plug the modular line cord from the...

Page 9: ...ne 50ms spacing HEARING AID COMPATIBILITY Meets EIA standards ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating TELEPHONE PANEL Brushed 16 gauge stainless steel DIMENSIONS 6 7 8 W...

Page 10: ...panel 1 371 014 Handset with coiled cord magnetic plate 1 928 001 Strain relief bushing 2 945 001 Magnetic reed switch assembly 1 341 018 Modular cord 2 371 009A Mounting support bracket 1 650 541 MC...

Page 11: ...Telephone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE T...

Page 12: ...rtment 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay...

Page 13: ...r replace any unit during this period if found to be defective for reasons other than abuse and improper use or improper installation It is the buyer s responsibility to return the defective unit to t...

Page 14: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BE...

Reviews: