TORQUE MEASUREMENT
TORQUE MEASUREMENT
SPECIFICATIONS
LIST OF EQUIPMENT
Torque Tester Display Unit
Torque Sensor
Cable
AC adapter/charger
Units designator
1
2
3
4
5
1
2
3
4
5
READ FIRST: SAFETY INFORMATION
For safety, and for damage avoidance, be sure to read this manual
thoroughly. The warranty is only valid when the product is used fol-
lowing the instructions provided within this manual.
l
Do not use tester in high temperature, high humidity, or in
damp or wet areas.
l
Recommended operating temperature is between 0-42ºC (32-
100ºF).
l
Do not apply torque exceeding the rated capacity, regardless of
whether the unit is On or Off.
l
When charging the battery, be sure to use the provided AC
adapter/charger exclusively.
l
When measuring torque, the unit will have a tendency to turn. In
order to avoid spinning and possible accident, it is very impor-
tant to securely mount the unit to a stable work bench.
l
Do not use lacquer thinner or any solvent to clean the unit.
l
Do not disassemble or modify the unit.
Model
lbf-in
kgf-cm
N-m
DI-1M-50
3.0~440.0
3.0~500.0
30~5000 (
N-cm)
DI-1M-200A
30~1800
30~2000
3.0~200.0
Model
lbf-ft
kgf-m
N-m
DI-1M-200
3.0~145.0
0.30~20.00
3.0~200.0
DI-1M-500
3.0~362.0
0.30~50.00
3.0~500.0
DI-1M Ranges
Accuracy: ±0.5% F.S. ±1 LSD
DIMENSIONS
A
B
C
D
E
F
G
DI-1M-50IP
∅
50 63 10
∅
90
∅
76
∅
6.5
9.5
(1.97
"
) (2.48
"
) (.39
"
) (3.54
"
) (2.99
"
) (.26
"
)
(3/8
"
Female Drive)
DI-1M-200IP
∅
60 72 10
∅
110
∅
90
∅
9.0
12.7
(2.36
"
) (2.83
"
) (.39
"
) (4.33
"
) (3.54
"
) (.35
"
)
(1/2
"
Female Drive)
DI-1M-500IP
∅
80 99
15.5
∅
140
∅
116
∅
10.5
19
(3.15
"
) (3.89
"
) (.61
"
) (5.51
"
) (4.57
"
) (.41
"
)
(3/4
"
Female Drive)