background image

26

REPLACEMENT PARTS

NOTE

: Use only original replacement parts. This will protect your warranty coverage for parts 

replaced under warranty.

PARTS UNDER WARRANTY

 

Contact authorized dealers of this product. If they can’t supply original replacement parts, call 

Customer Service toll free at 1-866-573-0674 for referral information. 

When calling Customer Service or your dealer, have ready:

• 

Your name

• 

Your address

• 

Model and serial number of your heater

• 

How heater was malfunctioning

• 

Type of gas used (Propane/LP or Natural gas/NG)

• 

Purchase date

Usually, we will ask you to return the defective part to the factory.

PARTS NOT UNDER WARRANTY

 

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call 

Customer Service toll free at 1-866-573-0674 for referral information.

When calling Customer Service have ready:

• 

Model number of your heater

• 

The replacement part number

Summary of Contents for 0051064

Page 1: ...vided Refer to Air For Combustion and Ventilation section on page 7 of this manual INSTALLER DO NOT DISCARD THIS MANUAL LEAVE FOR HOMEOWNER S FUTURE REFERENCE WARNING This appliance is equipped for Natural and Propane gas Field conversion is not permitted other than between natural or propane gases Questions problems missing parts Before returning to your retailer call our customer service departm...

Page 2: ...0 NG 28 000 LP Gas Type Using Natural Gas Using Natural Gas Using Natural Gas Pressure Regulator Setting 4 in W C 4 in W C 4 in W C Inlet Gas Pressure inches of water For purposes of input adjustment Maximum 10 5 in 10 5 in 10 5 in Minimum 5 in 5 in 5 in Gas Type Using Propane Gas Using Propane Gas Using Propane Gas Pressure Regulator Setting 9 in W C 9 in W C 9 in W C Inlet Gas Pressure inches of...

Page 3: ...e LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to operating this heater safely WARNING Any change to this fireplace heater or its controls can be dangerous WA...

Page 4: ... furniture 8 Always run heater with control knob at 1 2 3 4 5 locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monoxide may result 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been ...

Page 5: ...ed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts the gas cock must be a T handl...

Page 6: ... unvented room heater as the primary heat source PREPARING FOR INSTALLATION Before beginning assembly or operation of the product make sure all parts are present Compare parts with package contents list If any part is missing or damaged do not at tempt to assemble install or operate the product Contact customer service for replacement parts Before installing heater make sure you have the items lis...

Page 7: ...part of the unconfined space This heater should not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air f...

Page 8: ...r logs BTU hr Gas water heater 30 000 BTU hr Other gas appliances BTU hr Vent free heater 26 000 BTU hr Total BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used _______ BTU hr maximum the space can support _______ BT...

Page 9: ...r for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in...

Page 10: ...e impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc next to vinyl or cloth wall coverings WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air...

Page 11: ... located on back panel of heater see Fig 5 It has been taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mounting bracket to attach bracket to wall Attach mounting bracket to a wall only in one of two ways 1 Attaching to wall stud This method provides the strongest hold Insert mounting screws throug...

Page 12: ...Make sure mounting bracket is level WARNING Maintain minimum clearances shown in Fig 3 If you can provide greater clearances from floor and joining wall 2 Mark screw locations on wall see Fig 6 Note Mark only last hole on each end of mounting bracket Insert mounting screws through these holes only 3 Remove tape and mounting bracket from wall Only Insert Mounting Screws Through Last Hole On Each En...

Page 13: ...ng Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Fig 9 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket Installing Bottom Mounting Bracket 1 Install bottom bracket to heater bottom with two screws It may be more convenient to remove heater from wall bracket to attach 2 Place heater on wall mounting bracket 3 ...

Page 14: ...regulator damage could occur PROPANE MODELS CAUTION Never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting into gas piping and or fittings CAUTION Use pipe joint sealant that is resistant to gas Propane or...

Page 15: ...raps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly Installation of Base Feet Before installing heater to the base please make sure you have the following items 2 Base Feet 4 Sheet Metal Screws Fig 13 Installation Procedure 1 Set back of heater on table with the bottom of heater extending...

Page 16: ...ice 2 For NATURAL GAS press knob using a flat screwdriver with a blade with thickness of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 15 Fuel selection device must be locked in the NG position Do not operate heater between locked positions 3 Rotate and close cover over fuel selection device and reinstall screw 4 Remove hex plug with wrench provided from natur...

Page 17: ... leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig 17 2 Pressure supply piping system by either using compressed air or opening gas supply tank valve 3 Check all joints from gas meter to equipment shutoff valve see Fig 17 Apply mixture of l...

Page 18: ... DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push control Never use tools If the appliance does not operate don t try to repair it C...

Page 19: ...shooting pages 23 through 25 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match If control knob does not pop up when released contact a qualified service technician or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attached to the front of burner The p...

Page 20: ...ain constantly on AUTO position will be controlled by the temperature sensor To stop the operation turn rocker switch to the O position BATTERY INSTRUCTIONS CAUTION Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries Do not dispose of batteries in fire batteries may explode or leak Batteries are included Remove batteries when depleted ...

Page 21: ...ame Pattern with Control Knob Set to High Flame 5 Fig 20 Correct Pilot Flame Pattern Fig 21 Incorrect Pilot Flame Pattern WARNING If yellow tipping occurs your heater could produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the ...

Page 22: ...n If using compressed air in a can please follow the direc tions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Remove 4 screws 2 screws on each side of the front panel 3 Pull front panel forward 4 Blow air through the ports slots and holes in the burner Also clean...

Page 23: ...park at ODS pilot 1 Ignitor electrode is positioned wrong Ignitor electrode is broken 2 Ignitor electrode is not connected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 1 Replace electrode 2 Replace ignitor cable 3 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 4 Replace ignitor cable 5 Replace piezo ignitor When ignitor ...

Page 24: ... or contact customer service 2 Contact customer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 22 or Contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 ...

Page 25: ...or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 23 2 Gas leak See Warning Statement at the top of page 23 3 Low fuel supply 1 Ven...

Page 26: ...er Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll...

Page 27: ...1 2 2 Electrode ND0807 01 1 1 3 Pressure Regulator Assembly RV83FI 4 9 ASM 1 1 3 1 Pressure Regulator RV83FI 4 9 1 1 3 2 DF Regulator Bracket MML231 01 1 1 4 Fuel Selection Device Assembly LHY MD100TBF B 1 1 5 Fuel Selection Device Knob MDL304B 1 1 6 Regulator Plug PF120820 2 2 7 Grill Guard MEL2700A 1 1 8 Mounting Bracket MB060 02 1 1 9 Ignitor Assemebly PIMSC1 01 1 1 10 Bottom Bracket MEL232 1 1...

Page 28: ...Assembly RV83FI 4 9 ASM 1 1 3 1 Pressure Regulator RV83FI 4 9 1 1 3 2 DF Regulator Bracket MML231 01 1 1 4 Fuel Selection Device Assembly LHY MD200TBF B 1 1 5 Fuel Selection Device Knob MDL304B 1 1 6 Regulator Plug PF120820 2 2 7 Grill Guard MEL3133B 1 1 8 Mounting Bracket MB060 3P CG 1 1 9 Ignitor Assemebly PIMSC1 01 1 1 10 Bottom Bracket MEL5104 1 1 11 Base MEL514 CG 2 2 12 Glass Install Assemeb...

Page 29: ... Assembly RV83FI 4 9 ASM 1 1 3 1 Pressure Regulator RV83FI 4 9 1 1 3 2 DF Regulator Bracket MML231 01 1 1 4 Fuel Selection Device Assembly LHY MD300TBF B 1 1 5 Fuel Selection Device Knob MDL304B 1 1 6 Regulator Plug PF120820 2 2 7 Grill Guard MEL5136B 1 1 8 Mounting Bracket MB060 01 1 1 9 Ignitor Assemebly PIMSC1 01 1 1 10 Bottom Bracket MEL5104 1 1 11 Base MEL514 B 2 2 12 Glass Install Assemebly ...

Page 30: ...ing accessories not produced by the manufacturer are the purchaser s responsibility The manufacturer assumes no responsibility whatsoever for installation during the warranty period There is no further expressed warranty The manufacturer disclaims any and all implied warranties The manufacturer shall not be liable for incidental consequential or special damages arising at or in connection with pro...