11
LOCATING HEATER
This heater is designed to be mounted on a wall.
For convenience and efficiency, install heater:
1) Where there is easy access for operation,
inspection, and service.
2) In the coldest part of room.
INSTALLING THERMOSTAT SENSING BULB
(OPTIONAL)
1. Pull out the sensing bulb from the two clips
located in the shipping position. There
is no need to take out the two bulb clips.
2. Take out the bulb clip from the hardware
package and insert it into the square hole.
Then insert the sensing bulb into the bulb
clip (see Fig. 4).
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel
of heater (see Fig. 5).
It has been taped there for shipping. Remove
mounting bracket from back panel.
Methods For Attaching Mounting Bracket To Wall
Use only the last hole on each end of mounting bracket to attach bracket to wall. Attach
mounting bracket to a wall only in one of two ways:
1. Attaching to wall stud: This method provides the strongest hold. Insert mounting screws
through mounting bracket and into wall studs.
2. Attaching to wall anchor: This method allows you to attach mounting bracket to hollow walls
(wall areas between studs) or to solid walls (concrete or masonry).
3. Decide which method better suits your needs. Either method will provide a secure hold for the
mounting bracket.
Fig. 4 - Moving Thermostat Sensing Bulb
Fig. 5 - Mounting Bracket Location
Mounting Bracket