background image

No.

PART #

DESCRIPTION

ME10-GN

ME15-GN

1

B012A

HEYCO BUSHING STRAIGHT, SMALL 

1

1

2

B033A

TERMINAL BLOCK 3 POSITION

1

1

3

C032S

LINE CORD W/ PLUG 120V 15A

1

1

4

CD257

WATER INLET VALVE 120V

1

1

5

CH32A

THERMOSTAT HARNESS ASSEMBLY

1

1

6

CH415

WIRING HARNESS ASSEMBLY

1

1

7

D022Q

FAUCET, SHANK W/ VALVE

1

1

8

D031A

GUAGE SHIELD, 14 1/2" 

1

0

9

D066A

GUAGE SHIELD, 18" 

0

1

10

E009A

OVERFLOW FITTING W/ NUT

1

1

11

F091A

ORIFICE, LP 

(LP UNITS ONLY)

1

1

12

F124A

ORIFICE, NAT 

(NATURAL GAS UNITS ONLY)

1

1

13

F136A

PILOT HOUSING

1

1

14

F178A

THERMOPILE 24"

1

1

15

G052A

T-BURNER

1

1

16

H080A

TUBING, OVERFLOW - CU  5/8 X 16.5

0

1

17

H081A

TUBING, OVERFLOW - CU  5/8 X 13.5

1

0

18

H345A

PILOT TUBE 1/4" ALUMINUM

1

1

19

H346A

GAS VALVE TUBE 3/8" ALUMINUM

1

1

20

J015A

NIPPLE 3/8NPT x 4" BLACK STEEL

1

1

21

J040A

STREET ELBOW 3/8NPT BLACK STEEL

1

1

22

J041A

REDUCING COUPLING 3/8 x 1/8 

1

1

23

K039A

1/4 x 1/8 COMPRESSION FITTING

1

1

24

K088A

ORIFICE BODY 3305 R

1

1

25

K110A

NUT, 3/8 NPT CHROMIUM PLATED

1

1

26

K192A

FITTING ALUMINUM INLET 

 (NATURAL GAS UNITS ONLY)

1

1

27

K193A

FTG 1/8 NPT x 1/4 ANGLE

1

1

28

K491A

HOSE NUT ASSEMBLY (AMERICAN THREADS)

1

1

29

K525A

90 DEGREE ELBOW 1/2" TUBE

1

1

30

K549A

FITTING ALUMINUM INLET 

(LP UNITS ONLY)

1

1

31

K635A

ELBOW COMPRESSION FITTING 3/8 x 3/8 BRASS

2

2

32

K636A

HEX REDUCING BUSHING

1

1

33

K810Q

LEVEL SENSOR, DUAL PROBE

1

1

34

L007A

THERMOMETER BREW DIAL

1

1

35

L299A

ON - OFF SWITCH 20 AMP

1

1

36

L621A

GAS VALVE NAT. 

 (NATURAL GAS UNITS)

1

1

37

L622A

THERMOSTAT 

1

1

38

L690A

DUAL LEVEL CONTROL BOARD 120V

1

1

39

L347P

GAS VALVE LP. 

(LP UNITS ONLY)

1

1

40

M005S

LEGS, 4" ADJUSTABLE, (4/ SET)

1

1

41

M028A

KNOB, COVER

1

1

42

M326A

HOSE, WATER INLET 3/8 ID x 5/8 OD 15" LONG (FEET)

2

2

43

M461A

SEAL, SILICONE 12mm

1

1

44

M462A

SEAL, SILICONE 15mm

1

1

45

M607A

CLEAR GASKET

1

1

46

MA85A

BLACK KNOB, THERMOSTAT

1

1

47

P264A

SCREW, 10-24 X 1/2"   PAN HEAD, PHILLIPS    SST

2

2

48

P528A

WASHER

1

1

49

P810A

WING NUT, 10-24, SST

1

1

50

P813A

WASHER, S.S. (0.382 ID x 0.642 OD x .028 THK)

2

2

51

Q102A

COVER 

1

1

52

U019A

VENT CAP DRAIN

1

1

53

U160A

GAUGE SHIELD MOUNTING BRACKET

1

1

PARTS LIST

Summary of Contents for ME10-GN

Page 1: ...peration Manual NQ24A 12 2006 CONTENTS Specifications Start up Instructions Trouble Shooting Guide Parts List Wiring Diagram 18 Gauge Type 304L Stainless Steel construction to resist corrosion Solid State water level control for automatic refill ...

Page 2: ...RATURE CONTROL NOTE UNIT IS SUPPLIED WITH A GROUNDED 120V 15A LINE CORD AND PLUG NEMA 5 15P PROPANE GAS BTU HR 10 W C 12 000 NATURAL GAS BTU HR 3 5 W C GAS SPECIFICATIONS 12 000 MODEL NO ME10 GN ME15 GN GENERAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS A POWER SWITCH TEMPERATURE CONTROL GAS FLUE LINE CORD WITH PLUG GAS INLET 3 8 NPT 1 ...

Page 3: ... over the flue opening 4 Do not place combustibles or non combustible materials in the proximity of coffee urn as this could cause fires or obstruct air flow to the main burners 5 This installation must conform with local codes or in absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air o...

Page 4: ...ation label attached to the right side panel to be certain that the type of gas for which the unit is equipped is the same as the gas supply A 3 8 NPT gas connection is needed to connect the unit to the gas line An accessible manual shut off valve must be installed in the gas supply line in case of an emergency The gas supply pipe must be sized to accommodate all the gas fired equipment that may b...

Page 5: ... removal and cleaning FOR QUALIFIED SERVICE PERSONNEL ONLY THERMOSTAT CALIBRATION To adjust the temperature of the water in the urn turn the thermostat knob to 10 and remove the knob without moving the thermostat shaft Place narrow bladed screwdriver 1 8 into the hollow thermostat shaft and engage center adjustment screw When thermometer reading approaches 198F slowly turn the adjustment screw clo...

Page 6: ...g nut holding the burner to the frame Pull down the free burner end enough to clear the threaded stud and pull the burner horizontally away from the manifold orifice The burner can now be cleaned or replaced To reinstall reverse the above procedure BURNER MAITENANCE The burner should be cleaned both inside the venturi portion and on the outside using a soft bristle brush The burner must be replace...

Page 7: ......

Page 8: ......

Page 9: ... 25 K110A NUT 3 8 NPT CHROMIUM PLATED 1 1 26 K192A FITTING ALUMINUM INLET NATURAL GAS UNITS ONLY 1 1 27 K193A FTG 1 8 NPT x 1 4 ANGLE 1 1 28 K491A HOSE NUT ASSEMBLY AMERICAN THREADS 1 1 29 K525A 90 DEGREE ELBOW 1 2 TUBE 1 1 30 K549A FITTING ALUMINUM INLET LP UNITS ONLY 1 1 31 K635A ELBOW COMPRESSION FITTING 3 8 x 3 8 BRASS 2 2 32 K636A HEX REDUCING BUSHING 1 1 33 K810Q LEVEL SENSOR DUAL PROBE 1 1 ...

Page 10: ...t the terminals AC1 AC2 Your voltmeter should read 115 Volts It should read the same at terminals AC1 FILL when the water level is low This is the output power to actuate the coil of the Solenoid Valve to open it The lack of voltage at terminals AC1 L LEVEL or H LEVEL indicates that the Controller is not working properly 2 Make sure all wire connections are tight including ground 3 If after this t...

Page 11: ... WHT BLU YEL WATER LEVEL CONTROL WATER LEVEL PROBES GND 6 COMMON 4 L LEVEL 5 H LEVEL 3 AC 2N 1 FILL 2 AC 1L WATER LED L1 N WATER INLET VALVE POWER LIGHT GND GRN POWER SWITCH N L1 ELECTRICAL DIAGRAM ME10G N ME15G N 120 240 VOLTS ...

Reviews: