COMPONENTS TEST 

 

A)  Thermostat Adjustments: 
 
The Thermostat is factory set for proper dispense temperature  
of 190° F with the control shaft set to the maximum clockwise position. If field 
adjustments are needed proceed as follows: 
To DECREASE temperature, turn the control shaft slightly in the 
COUNTERCLOCKWISE direction. 
For qualified technicians ONLY: 
Remove the knob and locate the Slotted Adjustment Screw inside the hollow 
thermostat shaft.  Using a narrow-bladed screwdriver, engage slotted adjustment 
screw and turn it ¼ turn very slowly counterclockwise (CCW). Allow a few minutes 
for the temperature to reach set level.  The Heater Light will go ON, indicating the 
heating element is activated, wait for it to go OFF, indicating that the water has 
reached NEW set temperature. Take a temperature reading and repeat if necessary. 
 
B)    Water Inlet Valve Test 
        
Turn power OFF. If the water level rises inside a partially filled tank, the Water 
Inlet Valve is leaking.  Disconnect wires from the Water Inlet Valve coil and 
connect a 2 wire line cord to the terminals. Plug it into a 115V outlet.  If water 
flows in and stops when you pull it out, the Valve is working fine. Repeat this test 
a few times.  The problem may be in the Probe or Water Level Control Board.  If 
the water does not flow in when the cord is plugged into an electrical outlet, the 
Solenoid coil may be damaged, opened, or the valve may have an obstruction 
preventing the water from flowing in.  Clean or replace it. 
 
C)  Dual Probe Test 
      
If lack of water persists, first check incoming water flow rate, if flow rate is OK 
proceed as follows: 
Turn on the power and water supply.  Check inside the tank to make sure the water is 
below the Probe.  Pull the BLUE wire and terminal OFF the Probe rod.  If water still 
does not flow after the wire is disconnected from the Probe, the problem may be in 
the Solid State Dual Level Control Board.   
If water starts flowing into the tank, the Probe may be grounded, due to excessive 
liming.  Check with Ohm meter.  Clean or replace probe. 

 

D)  Dual Probe Liquid Level Controller Bench Test 
      
Check the Controller as follows: 
1.    Make sure there is power input to the Controller at the terminals AC1 & 
AC2 
Your voltmeter should read 115 Volts. It should read the same at terminals 
AC1 & FILL when the water level is low. This is the output power to actuate 
the coil of the Solenoid Valve to open it. The lack of voltage at terminals AC1 
& L-LEVEL or H-LEVEL indicates that the Controller is not working properly. 
2.   Make sure all wire connections are tight, including ground. 
3.   If after this, the Controller is still failing to open the Water Inlet Valve, 
replace it. 

Summary of Contents for GB1CP

Page 1: ...B1HC CP GB2HC CP GB1HC CP PC GB2HC CP PC GB1HC CP shown GB2 CP shown Cecilware sells value Worldwide 45 05 20th Avenue Long Island City NY 11105 Tel 1 718 932 1414 Fax 1 718 932 7860 1 800 935 2211 E...

Page 2: ...d operation the water level in the tank should not drop more than from the probe If it does the tank is not refilling fast enough Check the water line and water filter they may need cleaning or replac...

Page 3: ...e water inlet fitting of the valve 2 Plug the power cord into a proper receptacle 3 Activate the Power Switch Toggle Up The red power indicator light and the green dispense buttons will light up and t...

Page 4: ...be to catch the water dispensed 2 Push the dispense button and check the amount of product dispensed amount of water dispensed and time use stop watch to dispense that water 3 The amount of water disp...

Page 5: ...the Probe or Water Level Control Board If the water does not flow in when the cord is plugged into an electrical outlet the Solenoid coil may be damaged opened or the valve may have an obstruction pre...

Page 6: ...Gear See section VI C Damaged loose or missing Agitator Gear Replace Agitator Auger Gear See section VI D Inoperative Auger Motor or Relay Check connections of Motor Relay and or Switch if needed rep...

Page 7: ...hute and remove the hopper cover 3 Unscrew the rear auger nut and pull out the auger agitator wheel and spring 4 Follow the cleaning and sanitizing procedure above 5 Let dry all items and reassemble i...

Page 8: ...5 M461A 6 Silicone Seal 466 Id 6 K525A 3 Elbow 90 Ss 7 M326A 23 Hose Overflow 8 K695Q 1 Dual Probe Sub Assy 9 L573A 1 Hi Limit 220 F 10 SK89A 1 Tank Weldment 11 L467A 1 Dispense Valve 12 M324A 6 Hose...

Page 9: ...1 1 Heater Switch in Back of Machine Power Sw in Hopper Compartment L735A 1 2 3 Dispense Switch on Front Door L299A 1 Rinse Switch in Hopper Compartment K178A 1 Hose Nut Ass y not shown ITEM P N QTY...

Page 10: ...CECILWARE CORPORATION RED WHT BLU YEL GRN BLK WATER LEVEL CONTROL WATER LEVEL PROBES WATER FAN...

Page 11: ...CECILWARE CORPORATION RED WHT BLU YEL GRN BLK WATER LEVEL CONTROL WATER LEVEL PROBES WATER FAN...

Page 12: ...CECILWARE CORPORATION RED BLK WATER INLET VALVE WHT BLU YEL GRN WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER...