DESCRIPTION OF COMPONENTS: 

 

RINSE SWITCH.

  

With the door open, the rinse switch is located on the left side of the first Whipper Chamber next to the power switch.  

 

In the

 RINSE

 position it

 disengages the hopper motors

 and 

allows only water to be dispensed

       It is used for flushing out the Whipper Chambers and to adjust the water dispense valves for proper flow rates. 

 

HEATER SWITCH. 

This switch is 

located behind the cabinet in the rear of the unit..

 Its primary function is to shut off the heating element 

during the initial priming, start up operation of the machine, or whenever the tank is being drained for service.  

Note: Power Switch and Heater Switch must be ON in order for the elements to operate. 

 
POWER SWITCH. 

With the door open, the power switch is located on the left side of the first Whipper Chamber next to the Rinse Switch. The 
Power Switch controls all power to the machine including the heater elements.  

 

 

 WATER LEVEL CONTROLS.

  

Under normal conditions and operation, the water level in the tank should not drop more than ½" from the probe. If it does, 
the tank is not refilling fast enough.  Check the water line and water filter, they may need cleaning or replacing.

 

 
 

 
 

Mechanical Specifications 

 

Model # 

Label 

No. of 

Hoppers 

Hopper  

Capacity (lb.) 

Width 

(in.) 

Depth 

(in.) 

Height 

(in.) 

 Tank 
(Gal.) 

GB1CP

 

Cappuccino 

8 lb. 

7.75 

19

 

27 

GB2CP

 

Cappuccino 

4 lb. 

7.75 

19

 

27 

GB3CP

 

Cappuccino 

4 lb. 

9.88 

19

 

27 

GB1HC-CP

 

Hot Chocolate 

8 lb. 

7.75 

19

 

27 

GB2HC-CP 

Hot Chocolate 

4 lb. 

7.75 

19

 

27 

GB1HC-CP-PC 

Hot Chocolate 

8 lb. 

7.75 

19 

27 

GB2HC-CP-PC 

Hot Chocolate 

4 lb. 

7.75 

19 

27 

Add an additional 2.5” when installing with legs.   Add 2" for line cord and valve fitting clearance.        
Plumbing:  ¼” water line required. 

Electrical Specifications 

 

Model No.

 

 

Volts

 

 

Phase

 

 

Hz

 

 

Watts

 

Number of 

Heaters

 

 

Amps

 

Receptacle 

Nema No.

 

Circuit 

Breaker

 

GB1CP, GB2CP, GB3CP 

GB1HC-CP, GB2HC-CP 

GB1HC-CP-PC*,•GB2HC-CP-PC* 

120V 

50/60  1.8KW 

15 

5-15R 

15A 

* Automatic Portion Control 

For Wiring, refer to Wiring Diagrams. 

  

See Electrical Data Label attached to the back of the unit for proper voltages, breaker sizes   

and electrical outlet requirements for each model number listed.

 

Summary of Contents for GB1CP

Page 1: ...B1HC CP GB2HC CP GB1HC CP PC GB2HC CP PC GB1HC CP shown GB2 CP shown Cecilware sells value Worldwide 45 05 20th Avenue Long Island City NY 11105 Tel 1 718 932 1414 Fax 1 718 932 7860 1 800 935 2211 E...

Page 2: ...d operation the water level in the tank should not drop more than from the probe If it does the tank is not refilling fast enough Check the water line and water filter they may need cleaning or replac...

Page 3: ...e water inlet fitting of the valve 2 Plug the power cord into a proper receptacle 3 Activate the Power Switch Toggle Up The red power indicator light and the green dispense buttons will light up and t...

Page 4: ...be to catch the water dispensed 2 Push the dispense button and check the amount of product dispensed amount of water dispensed and time use stop watch to dispense that water 3 The amount of water disp...

Page 5: ...the Probe or Water Level Control Board If the water does not flow in when the cord is plugged into an electrical outlet the Solenoid coil may be damaged opened or the valve may have an obstruction pre...

Page 6: ...Gear See section VI C Damaged loose or missing Agitator Gear Replace Agitator Auger Gear See section VI D Inoperative Auger Motor or Relay Check connections of Motor Relay and or Switch if needed rep...

Page 7: ...hute and remove the hopper cover 3 Unscrew the rear auger nut and pull out the auger agitator wheel and spring 4 Follow the cleaning and sanitizing procedure above 5 Let dry all items and reassemble i...

Page 8: ...5 M461A 6 Silicone Seal 466 Id 6 K525A 3 Elbow 90 Ss 7 M326A 23 Hose Overflow 8 K695Q 1 Dual Probe Sub Assy 9 L573A 1 Hi Limit 220 F 10 SK89A 1 Tank Weldment 11 L467A 1 Dispense Valve 12 M324A 6 Hose...

Page 9: ...1 1 Heater Switch in Back of Machine Power Sw in Hopper Compartment L735A 1 2 3 Dispense Switch on Front Door L299A 1 Rinse Switch in Hopper Compartment K178A 1 Hose Nut Ass y not shown ITEM P N QTY...

Page 10: ...CECILWARE CORPORATION RED WHT BLU YEL GRN BLK WATER LEVEL CONTROL WATER LEVEL PROBES WATER FAN...

Page 11: ...CECILWARE CORPORATION RED WHT BLU YEL GRN BLK WATER LEVEL CONTROL WATER LEVEL PROBES WATER FAN...

Page 12: ...CECILWARE CORPORATION RED BLK WATER INLET VALVE WHT BLU YEL GRN WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER...

Reviews: