background image

EN

EN

SOLAR2R 

Standalone proximity keypad

2

cdvigroup.com

90

130

35

Poids (g) : 

Vol. (mm

3

) : 

Projet : ...

Plan d'ensemble

SOLARKPW

Etat de surface : Ra 3,2

Tolérance gale : 

 0.1

Matière : PC V0

DES.: A. Broustal

A3

ECHELLE 1:1

Date 23/07/2010

Edition 00

Plan M1849

31, av du Gal Leclerc

93691 PANTIN CEDEX

F  R  A  N  C  E

Tel : 33(0)148910102

Fax : 33(0)148912121

www.cdvi.com

Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.

This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

C.A. : 

F0101000072

147

124

55

IP52

CE certification

Remote electronics, supplied 

with the SOLAR2R keypad

-25°C to +70°C

1] GENERAL INFORMATION

 Construction: Polycarbonate

 Remote electronics

 Capacity of 1000 users

 Stored in non-volatile EPROM memory.

 Buzzer audible signal.

 Backlit keypad. 

 Sensitive touch keypad 

  3 Form «C» Relay outputs: 

 Adjustable time output : 

  1 to 99 seconds and toggle mode.

 Operating voltage: 12Vdc. 

 Consumption: 200mA.

 Surface-mount.

  Mounting  with Torx

®

 screws.

  Dimensions (L x W x D): 130 x 90 x 35 mm.

3] MOUNTING KIT

MOUNTING KIT

2] 

2] NOTES & RECOMMENDATIONS

Recommended power supplies.

- ADC335 (230V input), BS60 (230V input).

- Separate power supply for the control elements.

Wiring

- The distance between the keypad

  and the remote electronic can not exceed 

  more than 50 meters.

- Make sure that the cable is not near by a high

  voltage cables (ex: 230V ac). 

-

 

Recommended cable between the keypad 

  and the remote electronics: 2 twisted pairs  

  (4 wires) SYT1 0.8MM.

Mounting recommendations

Mount the keypad on a flat surface to avoid 

any vandalism and to insure the best mounting. 

In configuration two keypads, keep a minimum 

distance of 1m between the two keypads.

Security advice

- For security advice reasons, change 

  the factory default master code.

- When selecting a master code and user code  

  avoid simple codes (example : 

3 4 5 6 7

).

Back EMF protection

To secure the system from back electromagnetic 

fields do not forget to mount the varistor 

in parallel on the lock. 

 IP53

 -30°C to +70°C

 

Vibrations tests

 

IK10

Standalone 

Controller

Reader

Foam seal

M4x30

TF screw

S5

Plastic anchor

TORX

® 

bit

M3x8 TORX

®

  

screw

SOLAR2R

1

1

1

4

4

1

1

TMSOLAR2R

0

1

1

2

2

1

1

130

90

35

Summary of Contents for SOLAR2R

Page 1: ...1 FI NO DK SE EN SOLAR2R Standalone proximity keypad...

Page 2: ...Mounting with Torx screws Dimensions L x W x D 130 x 90 x 35 mm 3 MOUNTING KIT MOUNTING KIT 2 2 NOTES RECOMMENDATIONS Recommended power supplies ADC335 230V input BS60 230V input Separate power supply...

Page 3: ...back plate by using the supplied M3x8 Torx screw and T20 Trox spanner hardware Place the foam seal at the back of the reader Take care to begin from the bottom The foam seal must be visible about 2mm...

Page 4: ...utput voltage 12V dc 12V Output voltage 0V dc DOOR1 NO NO contact relay DOOR 1 C Common relay DOOR 1 NC NC contact relay DOOR 1 DOOR2 NO NO contact relay DOOR 2 C Common relay DOOR 2 NC NC contact rel...

Page 5: ...sure both dipswitches are positioned to off 1 reader configuration Press 1B the reader turns blue and position both dipswitches on the reader to ON 2 readers configuration Press 1B on the reader 1 and...

Page 6: ...A to pass the registration code OR Enter 5 terms 1 beep Green LED ON 1 beep Green LED ON 1 beep Green LED ON 90 130 35 Poids g Vol mm 3 Projet Plan d ensemble SOLARKPW Etat de surface Ra 3 2 Tol ranc...

Page 7: ...ault values Inter terms duration 10 seconds User code lenght 5 digits Mode cards or keypad Master code 1 2 3 4 5 Door duration 5 seconds Alarm duration 60 seconds Programming duration 30 seconds B A3...

Page 8: ...Str mf rbrukning 200mA Utanp liggande montage Monteras med Torx skruvar Dimensioner L x B x D 130 x 90 x 35 mm 3 MONTERINGSSATS MONTERINGSSATS 2 2 INFORMATION OCH REKOMMENDATIONER Rekommenderade n tag...

Page 9: ...TORX skruv och T20 nyckel S tt dit skruvens t cklock i nederkant av knappsatsen Placera skumt tningen mellan mon tageplattan och v ggen Skumt tningen skall vara synlig ungef r 2mm p toppen av mon tag...

Page 10: ...1 C Gemensam D RR 1 NC NC utg ng D RR 1 DOOR2 NO NO utg ng D RR 2 C Gemensam D RR 2 NC NC utg ng D RR 2 ALARM NO NO utg ng LARM C Gemensam LARM NC NC utg ng LARM BUS A Kabel A RS485 BUS B Kabel B RS4...

Page 11: ...knappsatserna st r i l ge OFF 1 knappsats Tryck 1B l saren lyser bl tt och st ll b da dipswitcharna i l ge ON 2 knappsatser Tryck 1B p knappsats 1 och 2B p knappsats 2 st ll sedan dipswitch n 2 p b da...

Page 12: ...in en 5 siffrig anv ndarkod 1 x pip Gr n LED P 1 x pip Gr n LED P 1 x pip Gr n LED P 90 130 35 Poids g Vol mm 3 Projet Plan d ensemble SOLARKPW Etat de surface Ra 3 2 Tol rance gale 0 1 Mati re PC V0...

Page 13: ...erhet Standardv rden Standby 10 sekunder Kodl ngd 5 siffror L ge kort eller kod Masterkod 1 2 3 4 5 Uppl sningstid 5 sekunder Larm utg ng 60 sekunder Programmerings timeout 30 sekunder B A3 F rdr jnin...

Page 14: ...EN SOLAR2R Standalone proximity keypad 14 cdvigroup com...

Page 15: ...EN SOLAR2R Standalone proximity keypad 15 cdvigroup com...

Page 16: ...GIUM NETHERLANDS LUXEMBOURG 32 0 56 73 93 00 www cdvibenelux com CDVI TAIWAN 886 0 42471 2188 www cdvichina cn CDVI SUISSE 41 0 21 882 18 41 www cdvi ch CDVI CHINA 86 0 10 84606132 82 www cdvichina cn...

Reviews: