Before commencing assembly, ensure you have the correct tools and accessories 

depending on the installation.

Position  the  box-section  backplate, 

complete  with  pre-fitted  electro-

magnetic  locks,  on  to  the  door  frame 

(or  fixed  door  leaf  if  installing  onto 

double doors) – ensure the positioning 

will  allow  for  the  archi-tectural  handle 

to close securely over the section. Once 

you  are  satisfied  with  the  position, 

mark  the  vertical  and  horizontal 

holes, then drill as required. Take note

 

of the cable entry holes, and feed 

the cables through. Fix the section into 

place,  then  wire  the  electromagnetic 

locks  in  accordance  with  the  wiring 

schematic  in  Section  5.  Fit  the  box 

section  cover  into  place,  fir  the  end 

caps  and  secure  with  the  M4  screws 

provided.

With  the  door  closed,  position  the 

architectural  handle  onto  the  edge  of 

the  opening  leaf  of  the  door,  ensuring 

the handle covers the box-section. Mark 

the  vertical  and  horizontal  holes,  drill 

as  required,  then  temporarily  fix  the 

handle leaving a small gap around the 

box  section  –  check  the  alignment  of 

the magnets in the box section with the 

magnets in the handle. 

Adjust if necessary, then once satisfied, 

secure the handle by completing 

the fixings.

To  finalise  the  assembly,  tighten  all 

fixings,  and  protect  the  handle  fixing 

section by fitting the cover and end caps. 

EN

BO800RN

Retrofit housing and retrofit handles

  iNstaLLatiON MaNUaL

3] MOUNtiNG Kit

4] assEMBLY

Profiled 

handle with 

end caps

Profiled 

handle 

fixings 

cover

Box section 

back-plate

Box section 

cover

End caps

screws kit

Manual

BO800RN

1

1

1

1

2

1

1

PBO400RN40

1

1

1

1

2

1

1

PBO800RN60

1

1

1

1

2

1

1

Summary of Contents for BO1200RN

Page 1: ...The installer s choice cdvigroup com BO800RN BO1200RN PBO800RN60 PBO400RN40 Retrofit housing and retrofit handles Bandeaux architecturaux et poign es ventouses ENGLISH EN FRANCAIS FR...

Page 2: ...ve at back of the magnet housing for easy wiring access Holding force Retrofit handles 400kg PBO400RN40 or 800kg PBO800RN60 Retrofit housing BO800RN from 2 5 to 4m 2 x 400kg End caps for the ends of t...

Page 3: ...ere is a rebate then it will be necessary to pack out the lower part Wiring Plan your cable routes before commencing installation We recommend a maximum distance of 10m from the power supply to the el...

Page 4: ...fir the end caps and secure with the M4 screws provided With the door closed position the architectural handle onto the edge of the opening leaf of the door ensuring the handle covers the box section...

Page 5: ...24Vdc 5 Way Terminal Strip monitored version 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative NC Contact Normally Closed COM Common NO Contact Normally Open Voltage 12Vdc or 24Vdc Place the jumpers to...

Page 6: ...6 cdvigroup com EN BO800RN Retrofit housing and retrofit handles INSTALLATION MANUAL 6 NOTES...

Page 7: ...cordement Passage des c bles facilit gr ce au bossage central l arri re du poteau technique support des ventouses Force de r tention Poign es 400 kg PBO400RN40 ou 800 kg PBO800RN60 bandeaux BO800RN de...

Page 8: ...n l aide de l option r f PRP800 Profil renfort avec poign e incorpor e et un cache vis ou ALMA C blage Pr voir du fil 9 10 souple Nous pr conisons une distance maximun de 10 m tres entre la ventouse e...

Page 9: ...et verticaux pour fixer la poign e bandeau Percer la surface de la porte au niveau des marques r a lis es Placez et vissez provisoire ment la poign e afin de laisser un l ger espace qui vous permettra...

Page 10: ...DC 12 V DC 12 V DC 24 V DC 24 V DC 24 V DC Bornier 5 points ventouse Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC NC Contact Normalement Ferm COM Commun NO Contact Normalement Ouvert Alim...

Page 11: ...11 cdvigroup com FR BO800RN Bandeaux architecturaux et poign es ventouses MANUEL D INSTALLATION 6 NOTES...

Page 12: ...CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI S...