background image

3

cdvigroup.com

Product Details

2] iNFORMatiON & RECOMMENDatiONs

information

The electromagnets are pre-fitted within the lock section. 

The armature plates are pre-fitted within the architectural 

handle. Both sections are supplied with end caps.

Power Considerations

The  handle  is  designed  to  house  electromagnets  with

 

a  holding  force  of  400Kg  each.  These  units  can  be 

supplied by either 12Vdc or 24Vdc depending upon your 

preferred choice. The current required depends on the 

amount of electromagnetic locks, and the voltage chosen 

–  please  see  Technical  Specification,  and  ensure  you 

have allocated sufficient power to correct performance. 

For  example,  the  BO800RN2.5m  (2.5m  housing  with

 

2 magnetic locks) would require:

- PSU12/2 or ARD2/12 at 12Vdc 

- PSU24/1 or ARD24 at 24Vdc.

 

General advice

The  2  parts  of  the  architectural  housing  are  designed 

to  be  surface mounted on  the  door  and  frame, where 

they should be parallel when the door is closed. If there 

is  a  rebate,  then  it  will  be  necessary  to  pack  out  the 

lower part.

Wiring

Plan your cable routes before commencing installation. 

We recommend a maximum distance of 10m from the 

power supply to the electromagnetic locks  (to prevent 

volt  drop).  If  the  distance  is  greater,  then  make  sure 

you  have  increased  the  cross  section  of  the  cable  to 

compensate.

Finishes

EN

BO800RN

Retrofit housing and retrofit handles

  iNstaLLatiON MaNUaL

BO800RN

PBO400RN40

PBO800RN60

DEsCRiPtiON

REtROFit HOUsiNG

REtROFit HaNDLE

REtROFit HaNDLE

Number of 400Kg 

magnets

2

1

2

Lock section with cover

1

1

1

Architectural handle 

with fixing cover

1

1

1

End caps for handle

2

2

2

End caps for lock section

2

2

2

RaL colour (option)

standard

(Ref. Product) 

aL

(Ref. Product) 

CH

(Ref. Product) 

9005

(Ref. Product) 

9010

(Ref. Product) 

Bt

Description

Anodised 

aluminium (SAA)

Anodised 

champagne

RAL

Black

RAL

White

Untreated

Number of 400Kg magnets

2

2

2

2

2

Lock section with cover

Architectural handle with 

fixing cover

End caps for handle

End caps for lock section

RaL colour (option)

-

-

-

-

Cut-to-length service 

provided (option)
Magnets & armatures supplied

non-mounted (specify)

-

-

-

-

Monitored (Option)

Summary of Contents for BO1200RN

Page 1: ...The installer s choice cdvigroup com BO800RN BO1200RN PBO800RN60 PBO400RN40 Retrofit housing and retrofit handles Bandeaux architecturaux et poign es ventouses ENGLISH EN FRANCAIS FR...

Page 2: ...ve at back of the magnet housing for easy wiring access Holding force Retrofit handles 400kg PBO400RN40 or 800kg PBO800RN60 Retrofit housing BO800RN from 2 5 to 4m 2 x 400kg End caps for the ends of t...

Page 3: ...ere is a rebate then it will be necessary to pack out the lower part Wiring Plan your cable routes before commencing installation We recommend a maximum distance of 10m from the power supply to the el...

Page 4: ...fir the end caps and secure with the M4 screws provided With the door closed position the architectural handle onto the edge of the opening leaf of the door ensuring the handle covers the box section...

Page 5: ...24Vdc 5 Way Terminal Strip monitored version 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative NC Contact Normally Closed COM Common NO Contact Normally Open Voltage 12Vdc or 24Vdc Place the jumpers to...

Page 6: ...6 cdvigroup com EN BO800RN Retrofit housing and retrofit handles INSTALLATION MANUAL 6 NOTES...

Page 7: ...cordement Passage des c bles facilit gr ce au bossage central l arri re du poteau technique support des ventouses Force de r tention Poign es 400 kg PBO400RN40 ou 800 kg PBO800RN60 bandeaux BO800RN de...

Page 8: ...n l aide de l option r f PRP800 Profil renfort avec poign e incorpor e et un cache vis ou ALMA C blage Pr voir du fil 9 10 souple Nous pr conisons une distance maximun de 10 m tres entre la ventouse e...

Page 9: ...et verticaux pour fixer la poign e bandeau Percer la surface de la porte au niveau des marques r a lis es Placez et vissez provisoire ment la poign e afin de laisser un l ger espace qui vous permettra...

Page 10: ...DC 12 V DC 12 V DC 24 V DC 24 V DC 24 V DC Bornier 5 points ventouse Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC NC Contact Normalement Ferm COM Commun NO Contact Normalement Ouvert Alim...

Page 11: ...11 cdvigroup com FR BO800RN Bandeaux architecturaux et poign es ventouses MANUEL D INSTALLATION 6 NOTES...

Page 12: ...CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI S...

Reviews: