background image

2

cdvigroup.com

1] PREsENtatiON

End Cap

Box section cover

Box section back plate

End plate

Profiled handle

Fixings cover

Profiled handle

Concealed fixing section

Fixing support

armature plate

Box section 

housing

Magnetic lock

400KG

EN

BO800RN

Retrofit housing and retrofit handles

  iNstaLLatiON MaNUaL

 NF S 61-937.

 Ultra-quick installation.

 Pre-drilled sections (adjustable).

 Pre-assembled.

 Attractive.

 Width overlapping the previous

  installations.

 Electromagnetic locks with

  terminal block.

 Groove at back of the magnet

  housing for easy wiring access.

  Holding force: 

  - Retrofit handles = 400kg (PBO400RN40)   

    or 800kg (PBO800RN60),

 

  - Retrofit housing BO800RN, from 2.5 to 4m  

    = 2 x 400kg.

 

  End caps for the ends of the handles

  and technical column.

  Options:

- three 400kg electromagnetic locks

  (Holding force: 1200kg - 12/24V dc),

- Installation on glass door: UBKU & UBK25,

- RAL colour,

- Cut. 

 

  Voltage: 12/24/48V dc.

  Consumption per 400kg electromagnetic lock:

  - 12V dc = 500mA.

  - 24V dc = 250mA.

  Consumption for the twice 400kg

  electromagnetic lock in 48V dc = 275mA.

Thank you for buying our products and for the confidence you placed

in our company.

CE Certification

WEEE

-20°C to +70°C

ARD212

ARD24

BS602

BS24

Recommended

Power supplies

Summary of Contents for BO1200RN

Page 1: ...The installer s choice cdvigroup com BO800RN BO1200RN PBO800RN60 PBO400RN40 Retrofit housing and retrofit handles Bandeaux architecturaux et poign es ventouses ENGLISH EN FRANCAIS FR...

Page 2: ...ve at back of the magnet housing for easy wiring access Holding force Retrofit handles 400kg PBO400RN40 or 800kg PBO800RN60 Retrofit housing BO800RN from 2 5 to 4m 2 x 400kg End caps for the ends of t...

Page 3: ...ere is a rebate then it will be necessary to pack out the lower part Wiring Plan your cable routes before commencing installation We recommend a maximum distance of 10m from the power supply to the el...

Page 4: ...fir the end caps and secure with the M4 screws provided With the door closed position the architectural handle onto the edge of the opening leaf of the door ensuring the handle covers the box section...

Page 5: ...24Vdc 5 Way Terminal Strip monitored version 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative NC Contact Normally Closed COM Common NO Contact Normally Open Voltage 12Vdc or 24Vdc Place the jumpers to...

Page 6: ...6 cdvigroup com EN BO800RN Retrofit housing and retrofit handles INSTALLATION MANUAL 6 NOTES...

Page 7: ...cordement Passage des c bles facilit gr ce au bossage central l arri re du poteau technique support des ventouses Force de r tention Poign es 400 kg PBO400RN40 ou 800 kg PBO800RN60 bandeaux BO800RN de...

Page 8: ...n l aide de l option r f PRP800 Profil renfort avec poign e incorpor e et un cache vis ou ALMA C blage Pr voir du fil 9 10 souple Nous pr conisons une distance maximun de 10 m tres entre la ventouse e...

Page 9: ...et verticaux pour fixer la poign e bandeau Percer la surface de la porte au niveau des marques r a lis es Placez et vissez provisoire ment la poign e afin de laisser un l ger espace qui vous permettra...

Page 10: ...DC 12 V DC 12 V DC 24 V DC 24 V DC 24 V DC Bornier 5 points ventouse Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC NC Contact Normalement Ferm COM Commun NO Contact Normalement Ouvert Alim...

Page 11: ...11 cdvigroup com FR BO800RN Bandeaux architecturaux et poign es ventouses MANUEL D INSTALLATION 6 NOTES...

Page 12: ...CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI S...