3800 Series Electric Mortise Lock Electrical  

Specifications and Supplemental Instructions

 

 

I-LS02200 

 

REV 2, 04/18/2018 

27390101 

Page 1 of 4 

FUNCTION DESCRIPTION

 

3880EL - Fail Safe Control

 

Outside trim is locked when power is applied and unlocked when power is removed (storeroom function when energized).  Lockset 

will unlock in the event of a power failure.

 

3880EU - Fail Secure Control

 

Outside trim is unlocked when power is applied and locked when power is removed.  Lockset will lock in the event of a power 
failure. This is the default lock setup.

 

Note:  3882 will function the same as the 3880EL / EU, but both sides will lock/unlock simultaneously.

 

Key Function

 

When key cylinders are installed into locks, the latch bolt may be momentarily retracted from the outside with key even if lockset is 

electrically locked.

 

Latch Bolt Monitoring

 

Latch Bolt Monitoring (LM) is a SPDT switch that is mounted inside the lockset.  The LM switch monitors the full extension of the 

main latch.  

 

Request to Exit

 

Request to Exit (RX) is a SPDT switch that is mounted inside the lockset.  The RX switch monitors the activation of the inside trim 

when the lockset is in the locked position only. 
 

Door Position Monitoring (DPM) 
Door Position Monitoring is a SPDT magnetic reed switch that is mounted in lock body and reacts with a magnet in the strike to 

monitor if the door is in the closed position. 

ELECTRICAL SPECIFICATIONS

 

EL and EU

 

RX and LM

 

DPM

 

Motorized Locking / Unlocking at 12/24V 
operation with low power consumption 

Voltage:  12-24V AC/DC (11V – 30V) 

Current:  250 mA MAX Inrush, 10 mA 

MAX holding 

Non-polarized leads 
Fail Secure by Default 

 

SPDT mechanical switch.  Mainly used as 

a dry contact monitoring switch.

 

Voltage  

Current 

 

125 VAC  

3 AMP 

30 VDC  

2 AMP

 

RX Wiring Diagram

 

Yellow Wire:  (common)

 

Red Wire:  (normally open)

 

Gray Wire:  (normally closed)

 

LM Wiring Diagram

 

Black: (common) 
Red: (closed loop secure) 

White: (open loop secure)

 

SPDT Magnetic Reed Switch (used as a 
dry contact monitoring switch) 

 
Voltage: 28 VDC 

Current: 0.300 A 
 

DPM Wiring Diagram 
WHITE WIRE – (COMMON) 

RED WIRE – (OPEN LOOP SECURE) 
GREEN WIRE – (CLOSED LOOP 
SECURE) 

 

 

Quick Connect Assignments: See page 4 for detailed pinning information 

 

 

2-Conductor Wire Run 

Distance 

12V/24V 

Wire 

Gauge 

125’/250’ 

22 

200’/400’ 

20 

300’/600’ 

18 

500’/1000’ 

16 

750’/1500’ 

14 

1250’/2500’ 

12 

 