background image

3800 Series Electric Mortise Lock Electrical  

Specifications and Supplemental Instructions

 

 

I-LS02200 

 

REV 2, 04/18/2018 

27390101 

Page 2 of 4 

Wire Bundles

See below for general location of wire bundles. Some or all of the bundles may be present depending on the functions ordered. When 
wiring up, use wire color within the bundle to identify function (see page 1 for function / wire details). 

 

Electrically Locked (EL) / Electrically Unlocked (EU) 

This function comes EU by default, but can be easily changed to EL by sliding the White switch from YELLOW to GREEN as shown 
below. The unit must have power applied at least once before the lockset changes state. Note that the latch bolt may be momentarily 
retracted by key even if the lockset is electrically locked. 

 

 

 

Door Position Monitoring (DPM)

 

 

Door position monitoring is an SPDT magnetic reed switch mounted inside the lockset with the activation magnet mounted behind the 
ANSI strike plate. The magnet is positioned above the latch bolt, so orient the magnet plate per handing of opening to properly 
position the magnet (see below for orientation). 

 

LEFT HAND STRIKE PLATE 

RIGHT HAND STRIKE PLATE 

 

 

 

Non-polarized Leads 

Default Fail-Secure (EU), Slide 
White Switch from YELLOW to 

GREEN to Make Fail-Safe (EL) 

EL/EU 

DPM 

LM &/or RX 

Activation Magnet 

TOP 

YELLOW  GREEN 

White Switch Slider 

Fail-Secure 

(EU) 

Fail-Safe 

(EL) 

NOTE: The colors indicate which direction to move the switch to select the desired function. 

They are not position indicators. The switch should be easy to move, so don’t force it. 