AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Recommended Wiring
Specifications
Equipment
Wire Type
Size
Maximum
Length
Zone input and output
2 conductors, copper 22AWG (0.64mm)
22AWG (0.64mm)
600m (2000ft .)
RS485 bus, Star or
Daisy Chain (no BIAS/
EOL required)
CAT 5/5e or 4 pairs
24AWG (0.51mm)
1220m (4000ft .)
4 conductors, copper
26AWG (0.40mm) to
18AWG (1.02 mm)
System Resources
Operating Temperature
-20°C to +70°C (-4°F to +158°F)
Humidity
0% to 85% (non condensing)
System Autonomy
Full Distributed Architecture (100% Off-line Operation)
Firmware
Online Upgradeable
PCB Dimensions
19.5cm (7.68”) x 8.9 cm (3.5”)
Cabinet Dimensions
29 cm (11.4”) high, 28 cm (11”) wide, 8 cm (3.15”) deep
Inputs
Multi-Purpose Inputs
10 zone inputs (up to 20 using ZONE DOUBLER) with optional individual WIRE CUT &
WIRE SHORT supervision.
Smoke Detector
Future use
Box Tamper
Normally Closed (N.C.) contact
Outputs
Multi-Purpose Outputs
10 outputs open collector 100mA
Communication
LOCAL BUS
RS485 @ 57600Baud supporting star and/or daisy chain topologies up to 4000ft (1220 meters)
Summary of Contents for AIOM
Page 1: ...AIOM The installer s choice cdvigroup com ENGLISH EN 10 Input 10 Output Module ...
Page 21: ...21 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...
Page 22: ...22 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...
Page 23: ...23 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...