background image

20

cdvigroup.com

EN

AIOM

10-Input/10-Output Module

  INSTALLATION MANUAL

EN

AIOM

10-Input/10-Output Module

  INSTALLATION MANUAL

7] Warranty  -  Terms & Conditions

The “5 Year Warranty” is offered by CDVI exclusively for CDVI products featuring the logo “5 Year Warranty”, 

and supplied by authorized CDVI dealers participating in the offer. You can obtain the address of the local 

authorized dealer participating in the offer by contacting CDVI or a local CDVI subsidiary. The “5 Year Warranty” 

is only applicable to hidden defects detected during the lifetime of the product, as defined by the CDVI Group (5 

years or 200 000 operations - whichever of the two expires first).
The “5 Year Warranty” conditions shall not modify the sales conditions between CDVI and its customers.

DURATION OF THE OFFER:

• This offer is valid from July 1st 2010; CDVI reserves the right to terminate this offer without prior 

notice .

• However, any product already registered up to the date of withdrawal of the offer will remain 

eligible for the “5 Year Warranty”.

• The warranty applies only to the available products mentioned in the above statement.

CONDITIONS :

• Hidden defects are guaranteed for an unlimited shelf life (period of time before use).
• To be eligible for the “5 Year Warranty”, the product must be registered at CDVI within one month 

of its delivery to the end user, by completing in and returning back the “warranty” form by fax, 

email or post to the local CDVI subsidiary. This information may also be registered on line at www.

cdvigroup.com.

• Only the issue of the “5 Year Warranty” certificate by CDVI can confirm product registration; CDVI 

may not be held responsible in the event of loss or non-presentation of the form.

• The “5 Year Warranty” only applies to products installed by a skilled and experienced personal 

with the necessary trade qualifications to install according to the highest standards, respecting 

the standards, instructions and guidelines defined by CDVI and according to the maximum 

recommended specifications.

• To enable CDVI to determine whether a product is eligible to claim for the “5 Year Warranty”, 

after prior issue of a return of materials authorization number (RMA) by CDVI, the customer must 

return the product and all of its accessories in the original packaging with a copy of its invoice. The 

transport fees shall be paid by the customer and the package must be returned to CDVI or to a 

CDVI authorized repair centre .

• Eligibility for the “5 Year Warranty” cover must be confirmed by CDVI.
• The “5 Year Warranty” only covers the replacement or repair of the parts acknowledged as faulty by 

CDVI .

• CDVI reserves the right to respect its obligation by replacing the product or the parts acknowledged 

as faulty by a standard part replacement or by a product or new parts, or by an updated or 

improved version of the product with identical or similar functionalities.

• In respect of the applicable law, CDVI cannot be held responsible for material or immaterial 

damages caused to goods or to third parties and as a direct or indirect result of the installation, 

utilization, product faults or poor functioning of a device.

• The “5 Year Warranty” is non-assignable and non-transferrable; only the person who registered the 

aforementioned warranty may benefit from the warranty.

• The “5 Year Warranty” is limited to the eligible product and is strictly limited to the conditions in 

effect on the date of purchase by the customer.

Summary of Contents for AIOM

Page 1: ...AIOM The installer s choice cdvigroup com ENGLISH EN 10 Input 10 Output Module ...

Page 2: ...put Module PC board 11 5 WIRING DIAGRAM 12 Connecting the Box Tamper Switches 12 Connecting Inputs 13 Examples of Input Connection Methods 14 Connecting Outputs 16 LED Indicators 17 Connecting the 10 Input 10 Output Module to the ATRIUM 2 Door Controller 18 6 WARRANTY TERMS CONDITIONS 19 Copyright C 2012 CDVI All rights reserved ATRIUM Access Control is protected by copyright law and international...

Page 3: ...M 2 Door Controller s AC22 anywhere on the 1220m 4000ft 4 conductor RS485 communication bus Effortless auto detect technology identifies the AIOM on the communication bus 10 Inputs 20 using zone doubling technology 10 Outputs Auto detect technology Up to 100 AIOM module can be connected to the AC22 1220m 4000ft 4 conductor RS485 expansion bus No jumpers or DIP switches Comprehensive LED status ind...

Page 4: ... listed readers Wiegand 26 bit 30 bit and 40 bit mag stripe up to 32 digits Use of a UL recognized tamper switch on every housing cabinet for the AIOM Use only UL listed cables Use only UL listed adaptors Note All circuits are power limited UL 294 Compliance Notice Use only UL listed power supply Connect CDVI LED status indicator part number 7020 0001 0000 to the DC Input gray terminals of the AIO...

Page 5: ...o 70 C 4 F to 158 F Humidity 0 to 85 non condensing System Autonomy Full Distributed Architecture 100 Off line Operation Firmware Online Upgradeable PCB Dimensions 19 5cm 7 68 x 8 9 cm 3 5 Cabinet Dimensions 29 cm 11 4 high 28 cm 11 wide 8 cm 3 15 deep Inputs Multi Purpose Inputs 10 zone inputs up to 20 using ZONE DOUBLER with optional individual WIRE CUT WIRE SHORT supervision Smoke Detector Futu...

Page 6: ...Output Module module in its cabinet with connection diagram label Metal Box kit Installation kit If any item is missing please notify your distributor immediately Wall Switch and a white wire 115mm with a log at each end Bolts and Nuts Wall Switch Spacer Door Switch and 2 white wire 350mm with a log at one end Door Switch Support Metal box screw Metal box lock and key Metal Box Kit 1 2 1 1 1 4 1 1...

Page 7: ...should be maintained Cabinet Dimensions 29 cm 11 4 high 28 cm 11 wide 8 cm 3 15 deep Multiple Conduit Knock outs Two 19 05mm 0 75 on each side and one 12 7mm 0 5 on top Minimum Clearance For Cabinet 25cm 10 clear space around all sides 38cm 15 clear space in front of cabinet Minimum Clearance From Electrical Interference 2 4m 8ft from high voltage equipment or wiring and from electrical equipment ...

Page 8: ...RUCTIONS Cabinet Side View Cabinet Door Nut Spacer Spacer Screw Spacer Install the wall tamper switch using the supplied bolts and nuts as shown in the following picture Install the tamper switch plastic spacer on the back at bottom left side of the box as show in the following picture ...

Page 9: ...bracket on the mounting flange Door Tamper Switch Bracket Door Tamper Switch Mounting Flange Install the door tamper switch by aligning the switch holes to the pre installed plastic bracket pins Press firmly to secure the tamper switch in position then fix the bracket to is mounting flange Refer to page for wiring diagram ...

Page 10: ...ture 1 Remove the box door knock out 2 Insert the lock in the hole 3 Slide the U metal part into the lock groove Alternatively or complementary to the box lock the box may be secured by fixing the cover to its base using screws However this should be done only once the installation of the 10 Input 10 Output Module system is completed 1 Use the 4 screws supplied to secure the box cover to its base ...

Page 11: ...ng the Box to its Location Install the box to its location using 4 screws not supplied as shown in the following picture If the wall tamper switch is used make sure that the tamper switch arm moves freely and is completely pushed in when the enclosure is installed on the wall ...

Page 12: ...ALLATION MANUAL Installing the 10 Input 10 Output Module PC board Install the 5 fasteners PCB holder supplied respectively to the box holes identified in red in the following picture INPUTS INPUTS OUTPUTS OUTPUTS TMP SMOKE LOCAL BUS AIOM Input Output Module ...

Page 13: ...end to the wall tamper switch terminal 2 Connect the other terminal of the door tamper switch to the TMP terminals using the supplied wire 3 Connect the other terminal of the wall tamper switch to the GND terminals using the supplied wire To use only one switch 1 Connect one terminal of the tamper switch to the TMP terminals using the supplied wire 2 Connect the other terminal of the same tamper s...

Page 14: ...t can be monitored Magnetic Door Contact Permits supervision of door status opened closed When using the default system settings you can easily swap terminals to troubleshoot the installation INPUTS INPUTS OUTPUTS O AIOM Input Output Module Input 6 1K Ohm OPTIONAL LOOP SUPERVISION 1K Ohm EOL Input 16 2 2K Ohm Input 1 Single Zone Setting Factory Default Settings Zone Doubling Settings Optional 10 Z...

Page 15: ...ble per INPUT in Software as described in the following figure This setup will not support WIRE CUT supervision but offers WIRE SHORT supervision and will generate an alarm condition when the state of the input is breached WIRE SHORT supervision YES Detected as INPUT SHORT WIRE CUT supervision NO Single with WIRE CUT Supervision Limit of 1 Detection Device on the Input When using this method only ...

Page 16: ... will support WIRE CUT supervision but not WIRE SHORT supervision and will generate an alarm condition when the state of one of the input is breached WIRE SHORT supervision NO WIRE CUT supervision YES Detected as INPUTS CUT Doubled with WIRE SHORT and WIRE CUT Supervision 2 Detection Device on the Input When using this method two device can be connected to the input The input must be connected usi...

Page 17: ...r less 12Vdc may be directly connected to the outputs Outputs can be configured as normally open deactivated or normally closed activated refer to the ATRIUM instruction manual for more information INPUTS OUTPUTS OUTPUTS TMP SMOKE LOCAL BUS AIOM Input Output Module RELAY Device AC or DC Source NC NO C Example of Devices Garage Door Lights Air conditioning Heating System Blinds Pump Locks See Recom...

Page 18: ...EDs are explained in the following pages INPUTS INPUTS OUTPUTS OUTPUTS TMP SMOKE LOCAL BUS AIOM Input Output Module 2 3 1 1 GLOBAL STAT Flash once per second Firmware is operating normally Flash rapidly Firmware is upgrading Inputs IN1 to IN10 Green LED Input breached Off LED Input normal OK Green LED flashing Input in trouble wire cut or wire short 2 OUTPUTS OUT1 to OUT10 Green LED Output activat...

Page 19: ...M 2 Door Controller s LOCAL BUS using Bus star and or daisy chain topologies For example cdvigroup com cdvigroup com cdvigroup com cdvigroup com cdvigroup com AC22 AIOM AIOM AIOM AIOM cdvigroup com cdvigroup com cdvigroup com cdvigroup com cdvigroup com AC22 AIOM AIOM AIOM AIOM cdvigroup com cdvigroup com cdvigroup com cdvigroup com cdvigroup com AC22 AIOM AIOM AIOM AIOM cdvigroup com cdvigroup co...

Page 20: ...ble in the event of loss or non presentation of the form The 5 Year Warranty only applies to products installed by a skilled and experienced personal with the necessary trade qualifications to install according to the highest standards respecting the standards instructions and guidelines defined by CDVI and according to the maximum recommended specifications To enable CDVI to determine whether a p...

Page 21: ...21 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...

Page 22: ...22 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...

Page 23: ...23 cdvigroup com EN AIOM 10 Input 10 Output Module INSTALLATION MANUAL NOTES ...

Page 24: ...hone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 0321 90 573 ...

Reviews: