EN
EN
9
CDV-96KP
2EASY 2-wire Video Door Station with Keypad
•
The default setting is * as the cancel button and # as confirm button,
please refer to */# function (8) setting below for detailed information.
•
Sliding a finger to touch the digital keypad may cause erroneous key
selection, use a direct finger press to select the digit required.
•
The “confirm” button # must be used after inputting the code number
each time otherwise the operation will be cancelled automatically in 10s.
Order
Setting item
Setting range
Default value Setting code
1
Reset all settings
-
1, 2, 3, 4
00
2
Setting the master code
1 - 12 digits
Valid keys: 0-9
1234
01
3
Setting the key illumination
time
10 to 99 seconds/
(00 = continually lit)
10 seconds
02
4
Setting the unlock time
1 to 99 seconds
1 second
03
5
Setting the unlock mode
0 = NO / 1 = NC
NO
04
6
Operation tone settings
0 = on / 1 = off
on
05
7
Reset code settings
-
1, 2, 3, 4
06
8
* & # function settings
0 = Normal / 1 = Reverse
Normal
07
9
Language
Valid keys: 0-9
Enable
08
10
Voice Volume
Valid keys: 0-9
5
09
11
MIC Volume Adjust
(microphone)
Valid keys: 0-9
7
10
12
SPK Volume Adjust
Valid keys: 0-9
4
11
13
Device Address
Valid keys: 0-3
0
12
14
Night Light Level
Valid keys: 0-5
4
13
15
Reserved
(not used)
Reserved
Reserved
14-17
16
Temporary code (single use
only) Password for relay 1
1-12 digits
Valid keys: 0-9
-
18
17
Temporary code (single use
only) Password for relay 2
1-12 digits
Valid keys: 0-9
-
19
18
Setting the code for user
group 1
1-12 digits
Valid keys: 0-9
-
20-59
19
Setting the code for user
group 2
1-12 digits
Valid keys: 0-9
-
60-99
20
Work Mode
0: Apartment /
1: Villa
1 (villa)
100
21
Call Address
Valid keys: 0-9
Villa: 00,16
Apartment: 00-31
101
22
Display Scene
Valid keys: 0-1
0
102
23
TS_Sensitivity (Touch
Screen)
Valid keys: 0-5
3
103